MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1194/jlr.p094763

Медицинская библиотека · Journal of lipid research · 2019

Potent reduction of plasma lipoprotein (a) with an antisense oligonucleotide in human subjects does not affect ex vivo fibrinolysis.

Boffa Michael B, Marar Tanya T, Yeang Calvin, Viney Nicholas J, Xia Shuting, Witztum Joseph L, Koschinsky Marlys L, Tsimikas Sotirios

Клиническое исследование I фазыКлиническое исследование II фазыСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

It is postulated that lipoprotein (a) [Lp(a)] inhibits fibrinolysis, but this hypothesis has not been tested in humans due to the lack of specific Lp(a) lowering agents. Patients with elevated Lp(a) were randomized to antisense oligonucleotide [IONIS-APO(a)Rx] directed to apo(a) (n = 7) or placebo (n = 10). Ex vivo plasma lysis times and antigen concentrations of plasminogen, factor XI, plasminogen activator inhibitor 1, thrombin activatable fibrinolysis inhibitor, and fibrinogen at baseline, day 85/92/99 (peak drug effect), and day 190 (3 months off drug) were measured. The mean ± SD baseline Lp(a) levels were 477.3 ± 55.9 nmol/l in IONIS-APO(a)Rx and 362.1 ± 89.9 nmol/l in placebo. The mean± SD percentage change in Lp(a) for IONIS-APO(a)Rx was -69.3 ± 12.2% versus -5.4 ± 6.9% placebo (P < 0.0010) at day 85/92/99 and -15.6 ± 8.9% versus 3.2 ± 12.2% (P = 0.003) at day 190. Clot lysis times and coagulation/fibrinolysis-related biomarkers showed no significant differences between IONIS-APO(a)Rx and placebo at all time points. Clot lysis times were not affected by exogenously added Lp(a) at concentrations up to 200 nmol/l to plasma with very low (12.5 nmol/l) Lp(a) levels, whereas recombinant apo(a) had a potent antifibrinolytic effect. In conclusion, potent reductions of Lp(a) in patients with highly elevated Lp(a) levels do not affect ex vivo measures of fibrinolysis; the relevance of any putative antifibrinolytic effects of Lp(a) in vivo needs further study.

Для цитирования: Boffa Michael B, Marar Tanya T, Yeang Calvin, Viney Nicholas J, Xia Shuting, Witztum Joseph L, Koschinsky Marlys L, Tsimikas Sotirios. Potent reduction of plasma lipoprotein (a) with an antisense oligonucleotide in human subjects does not affect ex vivo fibrinolysis.. Journal of lipid research. 2019. DOI: 10.1194/jlr.p094763.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.