International journal of molecular sciences · 2025
LC-MS/MS-Based Determination of Ambroxol in Human Plasma and Cerebrospinal Fluid: Validation and Applicability in a Phase II Study on GBA-Associated Parkinson's Disease Patients.
Клиническое исследование II фазыСтатьяМногоцентровое исследованиеРандомизированное исследованиеВалидационное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Franco Valentina, Palmisani Michela, Colucci Fabiana, De Micco Rosa, Aloisio Simone, Cazzaniga Federico, Cerri Silvia, Crema Francesca, Dattrino Francesca, Garavaglia Barbara, Gastaldi Matteo, Mitrotti Pierfrancesco, Moda Fabio, Rota Paola, Stiuso Rita, Tassorelli Cristina, Eleopra Roberto, Tessitore Alessandro, Valente Enza Maria, Avenali Micol, Cilia Roberto
Аннотация
Heterozygous mutations in the GBA1 gene, encoding the enzyme glucocerebrosidase (GCase), are major risk factors for Parkinson's Disease (PD). Ambroxol, a small chaperone originally used as a mucolytic agent, has been shown to cross the blood-brain barrier, enhance GCase activity, and reduce α-synuclein levels, making it a promising therapeutic candidate for disease-modifying effects in GBA1-associated PD (GBA1-PD). This study aimed to develop a method to quantify ambroxol levels in human plasma and cerebrospinal fluid (CSF) using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Ambroxol was determined by online solid-phase extraction (SPE), coupled with LC-MS/MS, by gradient elution on a monolithic column. Detection employed a 3200 QTRAP tandem mass spectrometer in the positive electrospray ionization mode. Calibration curves exhibited linearity across the analyzed ranges in both plasma and CSF. The recovery rate ranged from 106.7% to 113.5% in plasma and from 99.0% to 103.0% in CSF. No significant matrix effect was observed. Intra-day and inter-day precisions were below 11.8% in both matrices, and accuracy ranged from 89.9% to 103.1% in plasma and from 96.3% to 107.8% in CSF. We evaluated and confirmed the stability of the analyte in plasma and CSF across various storage conditions. The method was successfully validated according to European Medicine Agency (EMA) guidelines and its applicability was confirmed in the context of a multicenter, randomized, double-blind, placebo-controlled, phase II study, designed to monitor the ambroxol levels in the plasma and CSF of GBA1-PD.