MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijsu.2012.07.006

Медицинская библиотека · International journal of surgery (London, England) · 2012

Efficacy of ultrasonography in identification of non-recurrent laryngeal nerve.

Yetisir Fahri, Salman A Ebru, Çiftçi Burak, Teber Akif, Kiliç Mehmet

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this prospective study was to identify the arterial anomalies constantly associated with nonrecurrent inferior laryngeal nerve by preoperative ultrasonography and impact on recurrent inferior laryngeal nerve palsy (RILN).

METHOD: The study included 332 patients who underwent thyroidectomy or parathyroidectomy between 2009 February and 2011 October. Preoperative ultrasonography was performed to all patients to identify vascular anomalies related to NRILN. CT was performed only in patients with NRILN predicted with preoperative ultrasonography. Systematic nerve dissection was performed surgically. Patient characteristics, type of NRILN, preoperative and postoperative vocal cord mobility and morbidity were recorded.

RESULTS

The NRILN was identified in 6 patients on the right side (1.94%). Preoperative ultrasonography predicted NRILN in all cases (accuracy 100%).

CONCLUSION

Ultrasonography is a very reliable and simple method to be used in preoperative assessment to identify vascular anomaly associated with NRILN to make optimal surgical decisions against nerve damage in patients undergoing thyroidectomy or parathyroidectomy. Adequate surgical technique is of great importance.

Для цитирования: Yetisir Fahri, Salman A Ebru, Çiftçi Burak, Teber Akif, Kiliç Mehmet. Efficacy of ultrasonography in identification of non-recurrent laryngeal nerve.. International journal of surgery (London, England). 2012. DOI: 10.1016/j.ijsu.2012.07.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.