BACKGROUND: Current gold standard for the diagnosis of gastroesophageal reflux disease (GERD) is 24-hour pH metry though it fails to detect non-acidic reflux. The sensitivity of 24-hour pH metry alone (both catheter-based and Bravo capsule) is questionable, especially if gastric acid secretion is low due to reduced parietal cell mass, Helicobacter pylori-induced gastric atrophy and antisecretory therapy. Accordingly, we analyzed the diagnostic ability of 24-hour pH metry as compared to impedance monitoring in relation to the gastric pH without antisecretory therapy.

METHODS: A retrospective analysis of prospectively collected data from 150 patients with suspected GERD undergoing a 24-hour pH impedance study was done.

RESULTS: Among 150 patients with symptoms suggestive of GERD, 106 (70.6%) had confirmed GERD diagnosed either by 24-hour pH metry alone (10 [9.4%]), impedance monitoring alone (49 [46.2%]) or both (47 [44.3%]). Abnormal reflux of acidic and non-acidic gastric contents was detected by 24-hour pH metry and 24-hour impedance monitoring in 57/106 (53.7%) and 96/106 (90.5%) of patients, respectively (p < .00001). Patients with GERD diagnosed by 24-hour impedance monitoring had a higher mean gastric pH (2.9 [median 1.3, IQR 5.3]) than those diagnosed by 24-hour pH metry (2.1 [median 1.4, IQR 2.6]) or both (1.6 [median 1.2, IQR 2.1]) (p = 0.001).

CONCLUSION: Twenty-four-hour impedance monitoring detects GERD more often than 24-hour pH metry. Patients with higher mean gastric pH leading to non-acidic reflux were more often diagnosed by 24-hour impedance monitoring than 24-hour pH metry. Thus, 24-hour pH metry alone is inferior to additional impedance monitoring in the diagnosis of GERD, particularly in presence of reduced gastric acid secretion.