MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jped.2017.04.004

Медицинская библиотека · Jornal de pediatria · 2017

Heliox delivered by high flow nasal cannula improves oxygenation in infants with respiratory syncytial virus acute bronchiolitis.

Seliem Wael, Sultan Amira M

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study is to evaluate the hypothesis that use of heliox would result in improvement of gas exchange when used with high flow nasal cannula in infants with RSV acute bronchiolitis.

METHODS

All patients that met the inclusion criteria were randomized to either heliox (70:30) or air-oxygen mixture 30% via high flow nasal cannula at 8L/min for a continuous 24h. Measurements were taken at baseline, after 2h, and at the end of the 24h.

RESULTS

This prospective study included 48 patients. After 2h of treatment with heliox, the oxygen saturation and PaO2 significantly improved when compared with the air-oxygen group, 98.3% vs. 92.9%, 62.0mmHg vs. 43.6mmHg (p=0.04 and 0.01), respectively. Furthermore, PaO2/FiO2 ratio was significantly higher in the heliox group when compared with the air-oxygen group, 206.7 vs. 145.3. Nevertheless, CO2 showed better elimination when heliox was used, without significance. MWCA score dropped significantly in the heliox group, 2.2 points vs. 4.0 points in air-oxygen (p=0.04), 2h after starting the therapy.

CONCLUSION

Transient improvement of oxygenation in infants with RSV acute bronchiolitis during the initial phase of the therapy is associated with heliox when provided with HFNC, may provide a precious time for other therapeutic agents to work or for the disease to resolve naturally, avoiding other aggressive interventions.

Для цитирования: Seliem Wael, Sultan Amira M. Heliox delivered by high flow nasal cannula improves oxygenation in infants with respiratory syncytial virus acute bronchiolitis.. Jornal de pediatria. 2017. DOI: 10.1016/j.jped.2017.04.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.