MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circinterventions.125.015873

Медицинская библиотека · Circulation. Cardiovascular interventions · 2026

Transcatheter Pulmonary Valve Implantation With the Alterra Adaptive Prestent and SAPIEN 3 Transcatheter Heart Valve: 3-Year Pooled Outcomes of the ALTERRA Trials.

Torres Alejandro J, Dimas V Vivian, Shahanavaz Shabana, Balzer David, Morgan Gareth, Lim D Scott, Armstrong Aimee K, Berman Darren, Babaliaros Vasilis, Kim Dennis, Gillespie Matthew J, Sommer Robert, Aboulhosn Jamil, Jones Thomas K, Mahadevan Vaikom S, Stapleton Gary, Ma Ying, Shirali Girish, Parthiban Anitha, Blanke Philipp, Leipsic Jonathon, Zahn Evan

Контролируемое клиническое исследованиеСтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The Alterra Adaptive Prestent provides a landing zone for implantation of the 29 mm SAPIEN 3 transcatheter heart valve (THV) in patients with a dysfunctional right ventricular outflow tract (RVOT) to treat pulmonary regurgitation (PR). Here, we report 3-year outcomes from a pooled analysis of patients who underwent Alterra/SAPIEN 3 THV implantation enrolled in the ALTERRA pivotal trial, Continued Access Protocol, and Pulmonic Delivery System Registry.

METHODS

This multicenter, prospective trial enrolled patients with moderate or greater PR and RVOT/pulmonary valve anatomy suitable for implantation. The nonhierarchical composite end point of THV dysfunction was examined at 6 months: RVOT/pulmonary valve reintervention, moderate or greater PR, and mean RVOT/pulmonary valve gradient ≥35 mm Hg. Individual components of the composite, as well as additional clinical and echocardiographic outcomes were examined up to 3 years.

RESULTS

The Alterra/SAPIEN 3 THV system was implanted in 118 patients at 14 sites. At 6 months, THV dysfunction was 3.5% (4/113). At 3 years, 97.3% of patients in the valve implant population had freedom from reintervention, 100% of patients had a mean RVOT/pulmonary valve gradients <35 mm Hg, and 93.3% of patients had mild or lesser total PR. The Kaplan-Meier estimate of all-cause mortality was 3.5% at 3 years. There were no cases of coronary artery compression, hemopericardium, or endocarditis.

CONCLUSIONS

This analysis reports the longest follow-up in the largest cohort of patients from the ALTERRA trials. The Alterra Adaptive Prestent with the SAPIEN 3 THV system has shown excellent procedural outcomes and is effective in reducing PR at 3-year follow-up.

REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03130777.

Для цитирования: Torres Alejandro J, Dimas V Vivian, Shahanavaz Shabana, Balzer David, Morgan Gareth, Lim D Scott, Armstrong Aimee K, Berman Darren, Babaliaros Vasilis, Kim Dennis, Gillespie Matthew J, Sommer Robert, Aboulhosn Jamil, Jones Thomas K, Mahadevan Vaikom S, Stapleton Gary, Ma Ying, Shirali Girish, Parthiban Anitha, Blanke Philipp, Leipsic Jonathon, Zahn Evan. Transcatheter Pulmonary Valve Implantation With the Alterra Adaptive Prestent and SAPIEN 3 Transcatheter Heart Valve: 3-Year Pooled Outcomes of the ALTERRA Trials.. Circulation. Cardiovascular interventions. 2026. DOI: 10.1161/circinterventions.125.015873.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.