m+Medelevator.RU
← Поиск публикаций
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2019

Feasibility and safety of pulmonary vein isolation by high-power short-duration radiofrequency application: short-term results of the POWER-FAST PILOT study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Castrejón-Castrejón Sergio, Martínez Cossiani Marcel, Ortega Molina Marta, Escobar Carlos, Froilán Torres Consuelo, Gonzalo Bada Nerea, Díaz de la Torre Marta, Suárez Parga José Manuel, López Sendón José Luis, Merino José Luis

Аннотация

PURPOSE: Pulmonary vein (PV) isolation (PVI) by point-by-point radiofrequency application (PPRF) results in longer procedures than that achieved by single-shot ablation techniques. In addition, it is associated with significant risk of oesophageal injury. The POWER-FAST pilot study evaluated the feasibility and safety of PVI by high-power short-duration (HPSD) PPRF.

METHODS: HPSD PPRF around the PVs was done in 48 consecutive patients with atrial fibrillation. Fifty watts was delivered until a predefined lesion index value was reached (LSI ≥ 5 or Abl-I ≥ 350) and 60 W during 7-10 s in the first 18 and last 30 patients, respectively. A control group of 47 consecutive patients who had undergone PVI before the HPSD group with conventional PPRF (30 W for 30 s) was included for reference. Echocardiography and oesophageal endoscopy was performed shortly after ablation in all patients.

RESULTS: PVI of all targeted veins was achieved in 98% and 100% of patients of the conventional and HPSD groups, respectively (p = 0.59). Total radiofrequency time was 34 ± 11, 24 ± 8, and 15 ± 5 min in groups 30 W, 50 W, and 60 W (p < 0.001). Audible steam pops occurred in 4 out of 48 (8%) patients in the HPSD group, accounting for 4 (0.08%) out of 5 269 HPSD radiofrequency applications. No patient in the HPSD group developed pericardial effusion. The incidence of oesophageal lesions was 28%, 22%, and 0% in groups 30 W, 50 W, and 60 W, respectively (p = 0.007) CONCLUSIONS: PVI can be achieved with HPSD PPRF in most patients. This approach appears safe and associated with low risk of esophageal damage.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты