MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/clr.14463

Медицинская библиотека · Clinical oral implants research · 2025

Effect of Horizontal and Vertical Intraoral Scan Bodies on the Trueness of Complete-Arch Digital Implant Impressions: A Comparative In Vitro Study With Six Implants.

Azevedo Luís, Laureti Andrea, Marques Tiago, Pitta João, Fehmer Vincent, Pozzi Alessandro, Sailer Irena

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the interaction between intraoral scan body (ISB) type, operator, and intraoral scanner (IOS) selection on the trueness of complete-arch digital implant impressions. This study also compared horizontal ISBs (H-ISBs) and vertical ISBs (V-ISBs) across four IOS devices.

MATERIAL AND

METHODS

Digital impressions of a definitive mandibular cast with six multi-unit analogs were made using four H-ISBs from different manufacturers (denoted as H-NB, H-NS, H-M6, and H-SF), with a V-ISB (V-EA) as the reference. Each ISB was scanned using a desktop scanner and by two operators who scanned each ISB system 10 times using four IOS devices i5D, PS, T3, T4, generating 400 digital impressions. Deviations were measured using root-mean-square (RMS) error (α = 0.05).

RESULTS

All independent variables (operator, IOS, ISB) significantly affected trueness (p < 0.05). V-EA with i5D had the lowest trueness (78 [27] μm), while H-NS on PS showed the highest (12 [3] μm). H-M6 maintained high trueness across IOS devices. PS was the most stable IOS, while T4 showed the most variability.

CONCLUSIONS

Complete-arch digital impressions are influenced by ISBs, IOSs, and operators. H-ISBs demonstrated better trueness and consistency across IOSs and operators.

Для цитирования: Azevedo Luís, Laureti Andrea, Marques Tiago, Pitta João, Fehmer Vincent, Pozzi Alessandro, Sailer Irena. Effect of Horizontal and Vertical Intraoral Scan Bodies on the Trueness of Complete-Arch Digital Implant Impressions: A Comparative In Vitro Study With Six Implants.. Clinical oral implants research. 2025. DOI: 10.1111/clr.14463.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.