Clinical Performance, Safety, and Patient-Reported Outcomes of an Active Osseointegrated Steady-State Implant System.
СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Briggs Robert, Birman Catherine S, Baulderstone Nicholas, Lewis Aaran T, Ng Iris H Y, Östblom Anna, Rousset Alex, Tari Sylvia, Tong Michael C F, Cowan Robert
Аннотация
OBJECTIVE: To investigate the clinical performance, safety, and patient-reported outcomes of an active osseointegrated steady-state implant system that uses piezoelectric technology.
STUDY DESIGN: A prospective, multicenter, open-label, single-arm, within-subject clinical investigation.
SETTING: Three tertiary referral clinical centers located in Melbourne, Sydney, and Hong Kong.
PATIENTS: Twenty-nine adult subjects, 24 with mixed hearing loss or conductive hearing loss and 5 with single-sided sensorineural deafness.
INTERVENTION: Implantation with the Cochlear Osia 2 System.
MAIN OUTCOME MEASURES: Audiological threshold evaluation and speech recognition in quiet and in noise. Patient satisfaction and safety.
RESULTS: At 6-month follow-up after surgery, a mean improvement in pure-tone average of 26.0 dB hearing level and a mean improvement of 8.8 dB signal-to-noise ratio in speech reception threshold in noise was achieved with the investigational device as compared with the unaided situation. Usability of the investigational device was rated 71.4/100 mm for sound processor retention and 81.4/100 mm for overall comfort using a visual analog scale.
CONCLUSION: These outcomes confirm the clinical safety, performance, and benefit of an innovative active transcutaneous bone conduction implant using a piezoelectric transducer design in subjects with conductive hearing loss, mixed hearing loss, or single-sided sensorineural deafness.
STUDY DESIGN: A prospective, multicenter, open-label, single-arm, within-subject clinical investigation.
SETTING: Three tertiary referral clinical centers located in Melbourne, Sydney, and Hong Kong.
PATIENTS: Twenty-nine adult subjects, 24 with mixed hearing loss or conductive hearing loss and 5 with single-sided sensorineural deafness.
INTERVENTION: Implantation with the Cochlear Osia 2 System.
MAIN OUTCOME MEASURES: Audiological threshold evaluation and speech recognition in quiet and in noise. Patient satisfaction and safety.
RESULTS: At 6-month follow-up after surgery, a mean improvement in pure-tone average of 26.0 dB hearing level and a mean improvement of 8.8 dB signal-to-noise ratio in speech reception threshold in noise was achieved with the investigational device as compared with the unaided situation. Usability of the investigational device was rated 71.4/100 mm for sound processor retention and 81.4/100 mm for overall comfort using a visual analog scale.
CONCLUSION: These outcomes confirm the clinical safety, performance, and benefit of an innovative active transcutaneous bone conduction implant using a piezoelectric transducer design in subjects with conductive hearing loss, mixed hearing loss, or single-sided sensorineural deafness.