m+Medelevator.RU
← Поиск публикаций
Canadian journal of surgery. Journal canadien de chirurgie · 2001

Sentinel lymph-node biopsy for melanoma of the trunk and extremities: the McGill experience.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tremblay F, Louffi A, Shibata H, Meterissian S

Аннотация

OBJECTIVE: To determine the effectiveness of sentinel lymph-node (SLN) biopsy for melanoma of the trunk and extremities.

DESIGN: Case series review.

SETTING: Royal Victoria Hospital, a Canadian university hospital.

PATIENTS: Thirty-six patients (18 women and 18 men) seen between October 1996 and December 1998 with melanoma 1 mm or more in thickness with clinically negative lymph-node basins. Follow-up was 396 days.

INTERVENTIONS: SLN biopsy. Technetium-99m filtered sulfur colloid (0.5 mCi) was injected intradermally around the melanoma or the excision scar 10 to 15 minutes before the surgical skin preparation. The identification of the SLN(s) was done with a hand-held gamma probe. Local anesthesia was used mostly for inguinal SLN biopsy whereas general anesthesia was usually required for axillary SLN biopsy. Preoperative lymphoscintigraphy was used only for trunk melanomas.

OUTCOME MEASURES: Morbidity, successful identification of the sentinel node and locoregional recurrence.

RESULTS: The mean age of patients at diagnosis was 53.4 years (range from 22-76 yr). The melanomas were distributed between the lower extremities (20 patients), upper extremities (8 patients) and trunk (8 patients). The mean Breslow thickness was 2.35 mm (range from 1-8 mm). Lymphoscintigraphy accurately localized the lymph-node drainage basin for trunk melanomas. In 1 patient the SLN could not be identified because the radiocolloid failed to migrate (failure rate 2.8%). The average number of SLNs removed was 1.97. Eight patients (22%) had sentinel nodes positive for malignant disease. The postoperative complication rate was 8.5%. Seven of 8 patients with positive SLNs underwent a complete node dissection (1 patient refused). Of the completion dissections only 2 patients had positive non-SLNs. All patients with positive nodes received interferon alpha-2b as adjuvant treatment. At follow-up, 34 patients are alive with no evidence of disease, 1 patient with a positive SLN is alive with distant metastatic disease and 1 patient with a negative SLN is dead of disseminated disease.

CONCLUSION: SLN biopsy is a feasible technique with an acceptable failure rate and is thus a useful tool in the surgical management of melanoma.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты