MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/yct.0000000000000887

Медицинская библиотека · The journal of ECT · 2022

Seizure EEG Quality in Right Unilateral Ultrabrief ECT.

Yeap Samantha, Gupta Neeraj Kumar, Gill Shane, Dinesh Anthony, Woodman Richard John

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The aims of this study were to compare threshold and suprathreshold ictal electroencephalograms (EEGs) in right unilateral (RUL) ultrabrief (UB) electroconvulsive therapy (ECT) and to identify the differences between these EEGs.

METHODS

This study is a retrospective review of 125 pairs EEGs from titration and subsequent sessions across a 2-year period. All EEGs were independently rated for by 2 assessors using a scale based on qualities of an EEG used to guide ECT treatment dose adequacy, for example, midictal amplitude, regularity, interhemispheric coherence, seizure end point, and postictal suppression. The scores of threshold and suprathreshold EEGs were compared within and between groups based on 2 ECT types, that is, RUL UB ECT and RUL brief pulse (BP) ECT.

RESULTS

Paired t tests showed a statistically significant difference in between threshold and suprathreshold EEG scores in RUL UB ECT. There were no statistically significant differences between corresponding scores for RUL UB ECT and RUL BP ECT threshold and suprathreshold EEGs.

CONCLUSIONS

There is a significant difference between the quality of threshold and suprathreshold EEGs in RUL UB ECT when measured with an EEG rating scale. Visual rating of ictal EEGs is as reliable in discriminating between threshold and suprathreshold seizure in RUL UB ECT as it is in RUL BP ECT.

Для цитирования: Yeap Samantha, Gupta Neeraj Kumar, Gill Shane, Dinesh Anthony, Woodman Richard John. Seizure EEG Quality in Right Unilateral Ultrabrief ECT.. The journal of ECT. 2022. DOI: 10.1097/yct.0000000000000887.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.