m+Medelevator.RU
← Поиск публикаций
Annals of surgical oncology · 2023

Earlier Recurrence Detection Using Routine FDG PET-CT Scans in Surveillance of Stage IIB to IIID Melanoma: A National Cohort Study of 1480 Patients.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Helvind Neel Maria, Weitemeyer Marie Brinch-Møller, Chakera Annette Hougaard, Hendel Helle Westergren, Ellebæk Eva, Svane Inge Marie, Kjærskov Mette Wanscher, Bojesen Sophie, Skyum Helle, Petersen Søren Kjær, Bastholt Lars, Johansen Christoffer, Bidstrup Pernille Envold, Hölmich Lisbet Rosenkrantz

Аннотация

BACKGROUND: The effect of routine imaging in melanoma surveillance is unknown. In 2016, Denmark was the first country in the world to implement routine imaging with positron emission tomography-computed tomography with fluorodeoxyglucose (FDG PET-CT) in a nationwide, population-based surveillance program. This study aimed to determine the impact of surveillance with routine FDG PET-CT on hazard, cumulative incidence, and absolute risk of overall, locoregional, and distant recurrence detection in patients with stage IIB to IIID cutaneous melanoma.

METHODS: This retrospective, population-based, nationwide cohort study used prospectively collected data from five national health registries to compare hazard, cumulative incidence, and absolute risk of recurrence in patients with cutaneous melanoma diagnosed in 2008-2010 (cohort 1, followed with clinical examinations) and patients with cutaneous melanoma diagnosed in 2016-2017 (cohort 2, followed with clinical examinations and routine FDG PET-CT at 6, 12, 24, and 36 months).

RESULTS: The study included 1480 patients with stage IIB to IIID cutaneous melanoma. Cumulative incidences of overall and distant recurrence were higher in cohort 2, with a peak difference at three years (32.3 % vs 27.5 % and 25.8 % vs. 18.5 %, respectively). The hazard of recurrence was higher in cohort 2 during the first two years, with hazard rates for overall and distant recurrence of 1.16 (95 % confidence interval [CI], 0.93-1.44) and 1.51 (95 % CI, 1.16-1.96), respectively. The patterns persisted in absolute risk estimates.

CONCLUSIONS: Patients with stage IIB to IIID melanoma followed with routine FDG PET-CT had a 51 % increased hazard of distant recurrence detection within the first two years of surveillance. Future studies must determine whether this earlier recurrence detection translates into improved survival.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты