MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2015-308883

Медицинская библиотека · Heart (British Cardiac Society) · 2016

Cost-effectiveness of implantable cardiac devices in patients with systolic heart failure.

Mealing Stuart, Woods Beth, Hawkins Neil, Cowie Martin R, Plummer Christopher J, Abraham William T, Beshai John F, Klein Helmut, Sculpher Mark

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the cost-effectiveness of implantable cardioverter defibrillators (ICDs), cardiac resynchronisation therapy pacemakers (CRT-Ps) and combination therapy (CRT-D) in patients with heart failure with reduced ejection fraction based on a range of clinical characteristics.

METHODS

Individual patient data from 13 randomised trials were used to inform a decision analytical model. A series of regression equations were used to predict baseline all-cause mortality, hospitalisation rates and health-related quality of life and device-related treatment effects. Clinical variables used in these equations were age, QRS duration, New York Heart Association (NYHA) class, ischaemic aetiology and left bundle branch block (LBBB). A UK National Health Service perspective and a lifetime time horizon were used. Benefits were expressed as quality-adjusted life-years (QALYs). Results were reported for 24 subgroups based on LBBB status, QRS duration and NYHA class.

RESULTS

At a threshold of £30 000 per QALY gained, CRT-D was cost-effective in 10 of the 24 subgroups including all LBBB morphology patients with NYHA I/II/III. ICD is cost-effective for all non-NYHA IV patients with QRS duration <120 ms and for NYHA I/II non-LBBB morphology patients with QRS duration between 120 ms and 149 ms. CRT-P was also cost-effective in all NYHA III/IV patients with QRS duration >120 ms. Device therapy is cost-effective in most patient groups with LBBB at a threshold of £20 000 per QALY gained. Results were robust to altering key model parameters.

CONCLUSIONS

At a threshold of £30 000 per QALY gained, CRT-D is cost-effective in a far wider group than previously recommended in the UK. In some subgroups ICD and CRT-P remain the cost-effective choice.

Для цитирования: Mealing Stuart, Woods Beth, Hawkins Neil, Cowie Martin R, Plummer Christopher J, Abraham William T, Beshai John F, Klein Helmut, Sculpher Mark. Cost-effectiveness of implantable cardiac devices in patients with systolic heart failure.. Heart (British Cardiac Society). 2016. DOI: 10.1136/heartjnl-2015-308883.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.