m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2016

Feasibility and Safety of Transcatheter Aortic Valve Implantation Performed Without Intensive Care Unit Admission.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Leclercq Florence, Iemmi Anais, Lattuca Benoit, Macia Jean-Christophe, Gervasoni Richard, Roubille Francois, Gandet Thomas, Schmutz Laurent, Akodad Mariama, Agullo Audrey, Verges Marine, Nogue Erika, Marin Gregory, Nagot Nicolas, Rivalland Francois, Durrleman Nicolas, Robert Gabriel, Delseny Delphine, Albat Bernard, Cayla Guillaume

Аннотация

Admission to the intensive care unit (ICU) is a standard of care after transcatheter aortic valve implantation (TAVI); however, the improvement of the procedure and the need to minimize the unnecessary use of medical resources call into question this strategy. We evaluated prospectively 177 consecutive patients who underwent TAVI. Low-risk patients, admitted to conventional cardiology units, had stable clinical state, transfemoral access, no right bundle branch block, permanent pacing with a self-expandable valve, and no complication occurring during the procedure. High-risk patients included all the others transferred to ICU. In-hospital events were the primary end point (Valve Academic Research Consortium 2 criteria). The mean age of patients was 83.5 ± 6.5 years, and the mean logistic EuroSCORE was 14.6 ± 9.7%. The balloon-expandable SAPIEN 3 valve was mainly used (n = 148; 83.6%), mostly with transfemoral access (n = 167; 94.4%). Among the 61 patients (34.5%) included in the low-risk group, only 1 (1.6%) had a minor complication (negative predictive value 98.4%, 95% confidence interval [CI] 0.91 to 0.99). Conversely, 31 patients (26.7%) from the high-risk group had clinical events (positive predictive value 26.7%, 95% CI 0.19 to 0.35), mainly conductive disorders requiring pacemaker (n = 26; 14.7%). In multivariate analysis, right bundle branch block (odds ratio [OR] 14.1, 95% CI 3.5 to 56.3), use of the self-expandable valve without a pacemaker (OR 5.5, 95% CI 2 to 16.3), vitamin K antagonist treatment (OR 3.8, 95% CI 1.1 to 12.6), and female gender (OR 2.6, 95% CI 1.003 to 6.9) were preprocedural predictive factors of adverse events. In conclusion, our results suggested that TAVI can be performed safely without ICU admission in selected patients. This strategy may optimize efficiency and cost-effectiveness of procedures.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты