MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.hrthm.2016.03.009

Медицинская библиотека · Heart rhythm · 2016

Bipolar left ventricular pacing is associated with significant reduction in heart failure or death in CRT-D patients with LBBB.

Jamé Sina, Kutyifa Valentina, Aktas Mehmet K, McNitt Scott, Polonsky Bronislava, Al-Ahmad Amin, Zareba Wojciech, Moss Arthur, Wang Paul J

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

There are limited data on the significance of left ventricular (LV) lead pacing polarity to predict clinical outcomes.

OBJECTIVES

We aimed to determine the association between the LV lead pacing polarity for heart failure (HF) or death and ventricular tachyarrhythmias (VTA) in patients enrolled in MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy), receiving a cardiac resynchronization therapy device with implanted cardioverter-defibrillator (CRT-D).

METHODS

We retrospectively analyzed LV pacing polarity. Patients with LV bipolar leads paced between LV ring and LV tip were identified as True Bipolar, while those with LV bipolar leads paced between LV tip or LV ring and right ventricular coil or unipolar leads were identified as Unipolar/Extended Bipolar. Kaplan-Meier survival analyses and multivariate Cox proportional hazards regression models were used.

RESULTS

Of the 969 patients, 421 had True Bipolar pacing while the remainder (n = 548) had Unipolar/Extended Bipolar pacing. Among patients with left bundle branch block (LBBB), True Bipolar pacing was associated with lower cumulative incidence of death (P = .022) and HF/death (P = .046) compared to those with Unipolar/Extended Bipolar LV pacing. After adjustment for clinical covariates, bipolar LV pacing in LBBB patients was associated with 54% lower risk for death (HR: 0.46; 95% CI: 0.24-0.88; P = .020) and 32% lower risk for HF/death (HR: 0.68; 95% CI: 0.46-1.00; P = .048) compared to Unipolar/Extended Bipolar LV pacing, but not in those with non-LBBB. No association was seen with risk of ventricular tachyarrhythmia.

CONCLUSION

True Bipolar LV pacing configuration is associated with a significantly lower risk of HF/death and all-cause mortality in CRT-D patients with LBBB.

Для цитирования: Jamé Sina, Kutyifa Valentina, Aktas Mehmet K, McNitt Scott, Polonsky Bronislava, Al-Ahmad Amin, Zareba Wojciech, Moss Arthur, Wang Paul J. Bipolar left ventricular pacing is associated with significant reduction in heart failure or death in CRT-D patients with LBBB.. Heart rhythm. 2016. DOI: 10.1016/j.hrthm.2016.03.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.