Biton Yitschak, Goldenberg Ilan, Kutyifa Valentina, Baman Jayson R, Solomon Scott, Moss Arthur J, Szepietowska Barbara, McNitt Scott, Polonsky Bronislava, Zareba Wojciech, Barsheshet Alon

Аннотация

BACKGROUND: Relative wall thickness (RWT), defined as 2 times posterior wall thickness divided by the left ventricular (LV) diastolic diameter, is a measure of LV geometry and may be a marker for adverse events in patients with LV dysfunction.

OBJECTIVES: The aim of this study was to investigate the relationship between RWT and the risk for ventricular tachyarrhythmia (VA) in patients enrolled in the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) study.

METHODS: The study population comprised 1,260 patients with mild heart failure and left bundle branch block.

RESULTS: In a multivariable model, RWT was the most powerful echocardiographic measure for estimating the risk of VAs compared with commonly used echocardiographic variables. Patients with low RWT (<0.24) had 83% (p < 0.001) increased risk for VA and 68% (p < 0.001) increase in VA risk or death (VA/death) compared with patients with higher RWT values. Each 0.01-unit decrease in RWT was associated with 12% (p < 0.001) and 10% (p < 0.001) increases in the risk of VA and VA/death, respectively. Treatment with cardiac resynchronization therapy with defibrillator (CRT-D; CRT with implantable cardioverter-defibrillator) was associated with a greater increase in RWT compared with implantable cardioverter-defibrillator at 12 months (4.6 ± 6.8% vs. 1.5 ± 2.7%; p < 0.001), and every 10% increase in RWT in CRT-D patients was associated with 34% (p = 0.027) and 36% (p = 0.009) reductions in the risk of subsequent VA and VA/death, respectively.

CONCLUSIONS: In patients with mild heart failure and left bundle branch block, decreased RWT was associated with an increase in the risk of VA and VA/death. CRT-D therapy was associated with a favorable increase in RWT and reduction in risk of VA and VA/death. (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy [MADIT-CRT]; NCT00180271).