Short- and long-term need for permanent pacemaker after transcatheter implantation of the Edwards Sapien aortic valve prosthesis.

Moreno Raúl, Calvo Luis, Sánchez-Recalde Angel, Galeote Guillermo, Jiménez-Valero Santiago, López Teresa, Plaza Ignacio, González-Davia Rosa, Ramírez Ulises, Mesa Jose Maria, Moreno-Gomez Isidro, López-Sendón José-Luis

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

A permanent pacemaker is frequently needed after transcatheter aortic valve implantation, but the available data are mainly on the CoreValve system.

OBJECTIVE

To evaluate the need for new permanent pacemaker after implantation of the Edwards Sapien device, as well as related factors.

METHODS

We included the first 100 patients treated with the Edwards Sapien device at our institution. Of these, 12 had a permanent pacemaker before the procedure, and thus our study population was the remaining 88 patients.

RESULTS

A permanent pacemaker was indicated in eight patients (9.1%) during hospitalization or at 30 days. After discharge, another four patients needed a pacemaker (at 42 days and three, 18, and 30 months). Two variables were associated with the need for pacemaker during hospitalization: previous dialysis (13% vs. 1%, p=0.042) and complete right bundle branch block before the procedure (25% vs. 5%, p=0.032). More than one month after the procedure, the characteristics associated with the need for pacemaker were plasma creatinine level (2.5±1.7 vs. 1.3±0.6 mg/dl, p=0.001) and previous myocardial infarction (50% vs. 10%, p=0.013).

CONCLUSION

The rate of pacemaker implantation with the Edwards Sapien device was 9.1%. Right bundle branch block and dialysis were associated with this complication.

Для цитирования: Moreno Raúl, Calvo Luis, Sánchez-Recalde Angel, Galeote Guillermo, Jiménez-Valero Santiago, López Teresa, Plaza Ignacio, González-Davia Rosa, Ramírez Ulises, Mesa Jose Maria, Moreno-Gomez Isidro, López-Sendón José-Luis. Short- and long-term need for permanent pacemaker after transcatheter implantation of the Edwards Sapien aortic valve prosthesis.. Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology. 2015. DOI: 10.1016/j.repc.2015.05.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.