Open heart · 2015
Does the CHA2DS2-Vasc score predict procedural and short-term outcomes in patients undergoing transcatheter aortic valve implantation?
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Hamid Tahir, Choudhury Tawfiq R, Anderson Simon G, Hashmi Izhar, Chowdhary Saqib, Hesketh Roberts David, Fraser Douglas G, Hasan Ragheb, Mahadevan Vaikom S, Levy Richard
Аннотация
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is associated with periprocedural and postprocedural morbidity and mortality. Currently, there is a paucity of risk stratification models for potential TAVI candidates. We employed the CHA2DS2-Vasc score to quantify the risk of 30-day mortality and morbidity in patients undergoing TAVI.
METHODS AND RESULTS: A retrospective analysis of registry data for consecutive patients undergoing TAVI at 3 tertiary centres in Northwest England between 2008 and 2013. The CHA2DS2-Vasc score and its modification-the R2CHA2DS2-Vasc score, which includes pre-existing renal impairment and pre-existing conduction abnormality (right bundle branch block/left bundle branch block, RBBB/LBBB)-were calculated for all patients. A total of 313 patients with a mean age of 80 (79.1-80.8) years underwent TAVI. The implanted devices were either the CoreValve or the Edwards-SAPIEN prosthesis. The 30-day mortality was 14.3% in those with a CHA2DS2-Vasc score ≥6, whereas it was only 6.2% in those with a score <6 (p=0.04). Using the R2-CHA2DS2-Vasc score, the difference was more pronounced with a 30-day mortality of 22.6% in those patients with an R2-CHA2DS2-Vasc score ≥7 compared to 6.0% in those with a R2-CHA2DS2-Vasc score <7 (p=0.001). In multivariable Cox regression analyses, there was a significant and independent relationship between the CHA2DS2-Vasc score (hazard ratio (HR)= 2.71, (1.01 to 7.31); p<0.05) and the modified R2CHA2DS2-Vasc score (HR=4.27 (1.51 to 12.07); p=0.006) with 30-day mortality.
CONCLUSIONS: Our study demonstrates the potential use of the CHA2DS2-Vasc or the R2CHA2DS2-Vasc score to quantify the risk of mortality in patients undergoing TAVI. This could have significant implications in terms of clinical as well as patients' decision-making.
METHODS AND RESULTS: A retrospective analysis of registry data for consecutive patients undergoing TAVI at 3 tertiary centres in Northwest England between 2008 and 2013. The CHA2DS2-Vasc score and its modification-the R2CHA2DS2-Vasc score, which includes pre-existing renal impairment and pre-existing conduction abnormality (right bundle branch block/left bundle branch block, RBBB/LBBB)-were calculated for all patients. A total of 313 patients with a mean age of 80 (79.1-80.8) years underwent TAVI. The implanted devices were either the CoreValve or the Edwards-SAPIEN prosthesis. The 30-day mortality was 14.3% in those with a CHA2DS2-Vasc score ≥6, whereas it was only 6.2% in those with a score <6 (p=0.04). Using the R2-CHA2DS2-Vasc score, the difference was more pronounced with a 30-day mortality of 22.6% in those patients with an R2-CHA2DS2-Vasc score ≥7 compared to 6.0% in those with a R2-CHA2DS2-Vasc score <7 (p=0.001). In multivariable Cox regression analyses, there was a significant and independent relationship between the CHA2DS2-Vasc score (hazard ratio (HR)= 2.71, (1.01 to 7.31); p<0.05) and the modified R2CHA2DS2-Vasc score (HR=4.27 (1.51 to 12.07); p=0.006) with 30-day mortality.
CONCLUSIONS: Our study demonstrates the potential use of the CHA2DS2-Vasc or the R2CHA2DS2-Vasc score to quantify the risk of mortality in patients undergoing TAVI. This could have significant implications in terms of clinical as well as patients' decision-making.