Journal of electrocardiology · 2015
Selvester scoring in patients with strict LBBB using the QUARESS software.
Оценочное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Xia Xiaojuan, Chaudhry Uzma, Wieslander Björn, Borgquist Rasmus, Wagner Galen S, Strauss David G, Platonov Pyotr, Ugander Martin, Couderc Jean-Philippe
Аннотация
BACKGROUND: Estimation of the infarct size from body-surface ECGs in post-myocardial infarction patients has become possible using the Selvester scoring method. Automation of this scoring has been proposed in order to speed-up the measurement of the score and improving the inter-observer variability in computing a score that requires strong expertise in electrocardiography. In this work, we evaluated the quality of the QuAReSS software for delivering correct Selvester scoring in a set of standard 12-lead ECGs.
METHOD: Standard 12-lead ECGs were recorded in 105 post-MI patients prescribed implantation of an implantable cardiodefibrillator (ICD). Amongst the 105 patients with standard clinical left bundle branch block (LBBB) patterns, 67 had a LBBB pattern meeting the strict criteria. The QuAReSS software was applied to these 67 tracings by two independent groups of cardiologists (from a clinical group and an ECG core laboratory) to measure the Selvester score semi-automatically. Using various level of agreement metrics, we compared the scores between groups and when automatically measured by the software.
RESULTS: The average of the absolute difference in Selvester scores measured by the two independent groups was 1.4±1.5 score points, whereas the difference between automatic method and the two manual adjudications were 1.2±1.2 and 1.3±1.2 points. Eighty-two percent score agreement was observed between the two independent measurements when the difference of score was within two point ranges, while 90% and 84% score agreements were reached using the automatic method compared to the two manual adjudications.
CONCLUSION: The study confirms that the QuAReSS software provides valid measurements of the Selvester score in patients with strict LBBB with minimal correction from cardiologists.
METHOD: Standard 12-lead ECGs were recorded in 105 post-MI patients prescribed implantation of an implantable cardiodefibrillator (ICD). Amongst the 105 patients with standard clinical left bundle branch block (LBBB) patterns, 67 had a LBBB pattern meeting the strict criteria. The QuAReSS software was applied to these 67 tracings by two independent groups of cardiologists (from a clinical group and an ECG core laboratory) to measure the Selvester score semi-automatically. Using various level of agreement metrics, we compared the scores between groups and when automatically measured by the software.
RESULTS: The average of the absolute difference in Selvester scores measured by the two independent groups was 1.4±1.5 score points, whereas the difference between automatic method and the two manual adjudications were 1.2±1.2 and 1.3±1.2 points. Eighty-two percent score agreement was observed between the two independent measurements when the difference of score was within two point ranges, while 90% and 84% score agreements were reached using the automatic method compared to the two manual adjudications.
CONCLUSION: The study confirms that the QuAReSS software provides valid measurements of the Selvester score in patients with strict LBBB with minimal correction from cardiologists.