MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Archives des maladies du coeur et des vaisseaux · 1994

[Ambulatory measurement of blood pressure and plasma catecholamines in the study of orthostatic hypotension].

Chamontin B, Amar J, Bégasse F, Tran M A, Senard J M, Montastruc J L, Salvador M

Аннотация на английскомСтатьяПеревод пока не подготовлен

Аннотация

The purpose of the study was to investigate the interest of ambulatory blood pressure (BP) monitoring (ABPM) and plasma catecholamines in the management of orthostatic hypotension (OH). Fifteen patients, 4 men, 11 females, 53.3 +/- 21.1 years old, with OH were included in the study: 7 with dysautonomia (G1) = multiple systemic atrophy, pure autonomic failure, OH in elderly people; 8 with OH from other origin (G2) = hypovolemia, neurodystonia, vaso-vagal syncope. ABPM and plasma catecholamines assays (HPLC) in lying then in standing position were carried out in all patients. BP was 131.2 +/- 31.9/78.1 +/- 12.0 mmHg in lying and 112.1 +/- 25.3/75.4 +/- 15.8 in standing position (n = 15). The systolic (S) standing-induced (delta) decrease in BP after 1 min and 10 min (delta SBP) correlated with standard-deviation and variation coefficient of mean SBP (r = 0.78, p < 0.01; r = 0.82, p < 0.01 for delta sBP 1 min and r = 0.80, p < 0.01; r = 0.81, p < 0.01 for delta sBP 10 min), but not with norepinephrine (NorE) or epinephrine levels. There was a significant correlation between diastolic nycthemeral BP variability expressed by mean night-time DBP/mean day-time DBP ratio/diastolic N/D) and standing-induced decrease in DBP after 1 min (r = 0.59, p < 0.05). delta SBP 1 min and 10 min, delta DBP 1 min (p = 0.02, p = 0.05, p = 0.01) and systolic and diastolic N/D (p = 0.02; p < 0.01) were significantly different in G1 and G2.(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Chamontin B, Amar J, Bégasse F, Tran M A, Senard J M, Montastruc J L, Salvador M. [Ambulatory measurement of blood pressure and plasma catecholamines in the study of orthostatic hypotension].. Archives des maladies du coeur et des vaisseaux. 1994.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.