Annals of clinical biochemistry · 2011

Analytical evaluation of a high-sensitivity troponin T assay and its clinical assessment in acute coronary syndrome.

Клиническое исследованиеСравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Chenevier-Gobeaux Camille, Meune Christophe, Blanc Marie-Céline, Cynober Luc, Jaffray Patrick, Lefevre Guillaume

Аннотация

BACKGROUND: The recently developed, highly sensitive cardiac troponin T (hs-cTnT) immunoassay improves the detection of acute myocardial infarction (AMI). However, this assay requires further analytical and clinical evaluation.

METHODS: Imprecision, linearity, limits of quantification and interferences were evaluated; hs-cTnT was compared with a conventional cardiac troponin I assay (cTnI), performed on an X-pand(®)HM, in a population of patients with suspected AMI. Finally, the 99th percentile cut-off point for a reference population was explored in 213 healthy control subjects.

RESULTS: Imprecision analysis demonstrated coefficients of variation (CVs) below 4%, linearity showed a 0.999 coefficient of correlation, with excellent recovery (99.9%) and a limit of quantification (10%CV) was found at 9.2 ng/L. A negative interference (>20%) with haemolysis was observed when supplemental haemoglobin was above 0.25 g/dL. Patients with suspected AMI more frequently displayed an increased hs-cTnT (83%) than an increased cTnI (55%, P < 0.01). Unstable angina was present in 63% of patients with an increased hs-cTnT associated with no increase in cTnI. The 99th percentile value for our reference population was 16.9 ng/L. In 213 healthy blood donors, hs-cTnT levels were significantly correlated with age (P < 0.0001), and were higher in men than in women (P < 0.0001).

CONCLUSIONS: The analytical performance of hs-cTnT complied with the international guidelines for AMI detection. Determining the degree of haemolysis in a sample is of paramount importance to the interpretation of hs-cTnT results. The 99th percentile value of our reference population was established.