Is an intraaortic balloon pump a contraindication to robotic totally endoscopic coronary artery bypass?

Kon Zachary N, Lehr Eric, Odonkor Patrick, Fitzpatrick Molly, Zimrin David, Griffith Bartley, Bonatti Johannes

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

The success of robotic totally endoscopic coronary artery bypass (TECAB) in recent years has led to the expansion of the procedure to patients with more severe disease. Outcomes with these patients have not yet been well characterized, and no reports on TECAB performed in patients with a preoperatively placed intraaortic balloon pump (IABP) are available. We present our initial experience with this patient population.

PATIENTS AND

METHODS

We evaluated 5 patients with unstable angina or impaired left ventricular function requiring a preoperatively placed IABP who underwent TECAB using the daVinci telemanipulation system. Procedures were performed either on the beating heart using an endostabilizer (n = 2) or on the arrested heart using remote access perfusion and aortic balloon endoocclusion (n = 3). The median patient age was 67 years (range, 41-73 years), with a median preoperative ejection fraction of 43% (range, 26%-58%) and median EuroSCORE of 5 (range, 3-8).

RESULTS

There were no major intraoperative technical issues. The median length of stay in the hospital and intensive care unit was 8 days (range, 5-13 days) and 66 hours (range, 41-142 hours), respectively. There were no intraoperative or 30-day mortalities.

CONCLUSIONS

This early experience suggests that TECAB is feasible in patients with a preoperatively placed IABP. Both the beating heart and arrested heart versions can be used in this patient population, further broadening the spectrum of applicability of this procedure.

Для цитирования: Kon Zachary N, Lehr Eric, Odonkor Patrick, Fitzpatrick Molly, Zimrin David, Griffith Bartley, Bonatti Johannes. Is an intraaortic balloon pump a contraindication to robotic totally endoscopic coronary artery bypass?. The heart surgery forum. 2010. DOI: 10.1532/hsf98.20101152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.