High-risk PCI in acute coronary syndromes with Impella LP 2.5 device support.

Iliodromitis Konstantinos E, Kahlert Philipp, Plicht Bjorn, Hoffmann Andreas-Claudius, Eggebrecht Holger, Erbel Raimund, Konorza Thomas F

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate feasibility, safety, efficacy as well as acute and short-term outcome of hemodynamically supported percutaneous coronary intervention (PCI) by a percutaneous, catheter-based left ventricular assist device (LVAD) (Impella LP 2.5, Abiomed Europe GmbH, Aachen, Germany) in a high-risk patient population with acute coronary syndrome.

BACKGROUND

Although hemodynamic support by intraaortic balloon pump favorably affects myocardial oxygen supply and demand, it has modest effects on cardiac output, providing passive support only. In contrast, the Impella LP 2.5 microaxial pump, which is placed within the left ventricular outflow tract and actively ejects blood into the ascending aorta, might offer additional hemodynamic support and thereby procedural safety during PCI.

METHODS

Thirty-eight consecutive high-risk patients (mean age, 69.7 ± 10.3 years, logistic EuroSCORE, 22.4 ± 14.9%) with unstable angina pectoris or non-ST-segment elevation myocardial infarction and severe three-vessel-disease were included in the study. Clinical and laboratory examinations were performed at baseline as well as at 6, 24 and 48 h after the procedure and 30 days after discharge.

RESULTS

Device insertion and explantation was feasible in all patients without vascular complications and continuous hemodynamic stability was obtained during PCI. PCI was uneventfully performed in all but one patient for technical reasons. One non procedure-related death occurred 7 days after the intervention, accounting for a total 30-day mortality of 2.86%. Other major cardiac or cerebrovascular events did not occur.

CONCLUSIONS

LVAD support using a percutaneous microaxial flow pump is a promising and safe approach for high-risk PCI providing good short-term results.

Для цитирования: Iliodromitis Konstantinos E, Kahlert Philipp, Plicht Bjorn, Hoffmann Andreas-Claudius, Eggebrecht Holger, Erbel Raimund, Konorza Thomas F. High-risk PCI in acute coronary syndromes with Impella LP 2.5 device support.. International journal of cardiology. 2010. DOI: 10.1016/j.ijcard.2010.08.039.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.