MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13019-024-02643-9

Медицинская библиотека · Journal of cardiothoracic surgery · 2024

Investigation of the appropriate viscosity of fibrinogen in repairing pleural defects using ventilation and anchoring in an ex vivo pig model.

Fukuda Akihiro, Hashimoto Masaki, Takegawa Yoshitaka, Kondo Nobuyuki, Hasegawa Seiki

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Our previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods for controlling air leakages. Here, we examined the association between the viscosity of fibrinogen and effectiveness using an ex vivo pig model.

METHODS

The fibrin glue used in this study was BOLHEAL® (KM Biologics Co., Ltd., Kumamoto, Japan). We prepared three types of fibrinogen with different viscosities (higher and lower than normal), including one without additives. Using an ex vivo pig model, a pleural defect was made, and the defect was repaired using three different viscosities of fibrinogen through the V/A method. We measured the rupture pressure at the repair site (N = 10) and histologically evaluated the depth of fibrin infiltration into the lung parenchyma at the repair sites.

RESULTS

The median rupture pressure was 51.5 (40-73) cmH2O in Group 1 (lower viscosity), 47.0 (47-88) cmH2O in Group 2 (no change in viscosity), and 35.5 (25-61) cmH2O in Group 3 (higher viscosity). There was no statistically significant difference between Groups 1 and 2 (p = 0.819), but the rupture pressure was significantly higher in Group 2 than in Group 3 (p = 0.0136). Histological evaluation revealed deep infiltration of fibrin into the lung parenchyma in Groups 1 and 2, but no such infiltration was observed in the higher-viscosity group.

CONCLUSIONS

The results of this experiment suggested that the V/A method using fibrin glue containing low-viscosity fibrinogen was more effective in controlling air leakage due to pleural defects.

Для цитирования: Fukuda Akihiro, Hashimoto Masaki, Takegawa Yoshitaka, Kondo Nobuyuki, Hasegawa Seiki. Investigation of the appropriate viscosity of fibrinogen in repairing pleural defects using ventilation and anchoring in an ex vivo pig model.. Journal of cardiothoracic surgery. 2024. DOI: 10.1186/s13019-024-02643-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.