m+Medelevator.RU
← Поиск публикаций
The American journal of cardiology · 2019

Effect of Successful Edge-to-Edge Mitral Valve Repair on Ventricular Arrhythmic Burden in Patients With Functional Mitral Regurgitation and Implantable Cardiac Devices.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Benito-González Tomás, Estévez-Loureiro Rodrigo, Garrote-Coloma Carmen, Arellano-Serrano Carlos, Tundidor-Sanz Elena, Fernández-Lozano Ignacio, Toquero Jorque, Pérez de Prado Armando, Goicolea Javier, Fernández-Vázquez Felipe

Аннотация

Significant mitral regurgitation (MR) may be present in up to half of patients with heart failure (HF) and it is associated with adverse cardiac remodeling and myocardial stretch. These are potential triggers for ventricular arrhythmias (VA) in patients with HF, and therefore MR may enhance electrical ventricular vulnerability. Our aim was to evaluate VA burden before and after percutaneous mitral valve repair (PMVR) in patients with implantable cardiac devices. We conducted a prospective registry of all consecutive patients (n = 34, age 69.0 ± 12.2 years, 77% male) with significant functional mitral regurgitation (FMR) who underwent MitraClip implantation in 2 centers between June 2014 and July 2018. VA burden was defined as the total number of events during device follow-up before and after PMVR. Among patients presenting VA during follow-up before or after PMVR, device success at hospital discharge was related to a significant reduction in the incidence of Nonsustained ventricular tachycardia (VT, p = 0.002) and any sustained VT or rapid VT/ventricular fibrillation (p = 0.034). Regarding implantable cardiac defibrillator (ICD) therapies, successful PMVR was related to a reduction in incidence of either antitachycardia pacing or appropriate shocks (p = 0.045) and in the occurrence of any defibrillation shocks (p = 0.045). Overall, effective repair lead to a significant reduction in the VA burden, with a significant decrease in the occurrence of any VA (p = 0.004) and any ICD therapies (p = 0.045). In conclusion, device success after PMVR was related to a reduction in overall arrhythmic burden and ICD therapies in our cohort.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты