Coronary Injury in Mitral and Aortic Valve Surgery: A Case Series Using Optical Coherence Tomography.

Scarsini Roberto, De Maria Giovanni Luigi, Ciofani Jonathan, Jin Xu Yu, Sayeed Rana, Petrou Mario, Banning Adrian

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

Coronary occlusion is a rare but well-described complication of heart valve surgery. The left circumflex coronary artery, especially when it is dominant, is particularly at risk owing to the proximity of the mitral valve annulus. We report three cases of acute coronary complications of different valvular surgical procedures diagnosed and treated in the cardiac catheterization laboratory. Intracoronary optical coherence tomography was used to identify the cause of coronary flow impairment and provided important insights into the mechanism of intraoperative vascular damage.

Для цитирования: Scarsini Roberto, De Maria Giovanni Luigi, Ciofani Jonathan, Jin Xu Yu, Sayeed Rana, Petrou Mario, Banning Adrian. Coronary Injury in Mitral and Aortic Valve Surgery: A Case Series Using Optical Coherence Tomography.. The Annals of thoracic surgery. 2019. DOI: 10.1016/j.athoracsur.2019.05.085.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.