BACKGROUND

Sighing has been proposed as a primary respiratory reset mechanism that is often linked to emotional regulation. However, evidence linking sighing to anxiety relies heavily on laboratory studies, which lack ecological validity. It remains unclear whether ambulatory sighing dynamics in free-living settings reflect momentary (state) symptom fluctuations or enduring (trait) pathology. Evidence from daily-life monitoring is needed to evaluate sighing dynamics as a candidate digital biomarker for anxiety disorders (ADs).

OBJECTIVE

This study aimed to evaluate daily-life sighing dynamics as a candidate digital biomarker of anxiety by disentangling state and trait anxiety-sigh associations and comparing these dynamics between individuals with ADs and healthy controls (HCs). A secondary objective was to assess the feasibility, signal quality, and joint data coverage of a synchronized ecological momentary assessment (EMA) and respiratory inductance plethysmography (RIP) protocol.

METHODS

We conducted an intensive longitudinal study integrating smartphone-based EMA with continuous RIP using a Hexoskin smart shirt. Thirty-eight adults were enrolled (n=15 with ADs; n=23 HCs) and completed four 36-hour intensive monitoring blocks distributed over 1 to 2 weeks. Participants wore the Hexoskin RIP smart shirt during each 36-hour block and completed 6 randomly timed EMA prompts per day during the daytime hours (9 AM to 9 PM). Sighs were operationally defined as breaths with tidal volume ≥2 × each participant's median tidal volume. Each EMA entry was linked to the preceding 5-minute respiratory window, and the primary outcome was sigh proportion (sigh breaths/total breaths) per window. Multilevel generalized linear mixed models were used to analyze anxiety-sigh coupling, decomposing anxiety into within-person (state) and between-person (trait) components.

RESULTS

The analysis included 1279 synchronized psychophysiological windows from 33 participants. Five participants were excluded due to insufficient valid synchronized windows. In the primary beta-binomial model of sigh proportion, higher between-person (trait) anxiety was significantly associated with a lower overall sigh proportion (odds ratio [OR] 0.80, 95% CI 0.74-0.87; P<.001), while HCs showed a lower baseline sigh probability than the anxiety disorder group (OR 0.78, 95% CI 0.65-0.93; P=.005). The within-person anxiety-by-group interaction was significant (OR 1.14, 95% CI 1.03-1.26; P=.01), indicating that sighing tended to increase with higher momentary anxiety in HCs but was attenuated in participants with ADs. Feasibility was high (EMA completion: 1626/2046, 79.5%; high-quality respiratory samples: 10.85/12.90 million, 84.1%; EMA-RIP linkage: 1319/1626, 81.1%).

CONCLUSIONS

Daily-life sighing dynamics showed a state-trait dissociation, with reduced state-dependent coupling in ADs versus HCs, supporting sighing as a candidate digital biomarker of anxiety. The synchronized EMA-RIP protocol was feasible and yielded high-integrity real-world data.

Для цитирования: Zhao Xinying, Li Yue, Zhang Lizhu, Wang Jiafeng, Jialin Anfeirea, An Qi, Fu Yunfan, Yao Cheng, Deng Wei. Sighing Dynamics as a Candidate Digital Biomarker for Anxiety in Daily Life Using Wearable Respiratory Monitoring: Intensive Longitudinal Study.. JMIR formative research. 2026. DOI: 10.2196/89485.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.