Repetitive nerve stimulation often fails to detect abnormal decrement in acute severe generalized Myasthenia Gravis.

Liik Maarika, Punga Anna Rostedt

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

We assessed the diagnostic pattern of repetitive nerve stimulation (RNS) test and concentric electrode (CNE) jitter analysis between patients with generalized myasthenia gravis (GMG) with acute versus slow onset.

METHODS

All examinations that established the diagnosis of GMG at the department of Clinical Neurophysiology, Uppsala University Hospital, were retrospectively analyzed from January 2012 to December 2014. Patients were grouped according to disease duration at neurophysiological evaluation: acute onset (<4weeks) or slow onset (⩾4weeks).

RESULTS

We identified 41 patients diagnosed with GMG. Of the nine patients with acute onset GMG (5 women) only one patient had abnormal decrement, whereas of the 32 patients with slow onset (13 women) 26 patients (84%) had abnormal decrement. CNE jitter was abnormal in all. AChR antibody status was comparable (78% versus 84%) whereas the MGFA class was higher in the acute onset group (range: 3A-5) compared to the slow onset group (range: 2A-3B).

CONCLUSIONS

RNS test is frequently normal in cases of acute severe GMG, including myasthenic crisis. Performing CNE jitter analysis is therefore of crucial importance for a correct early diagnosis.

SIGNIFICANCE: MG patients with acute severe onset of bulbar or generalized fatigue often have normal findings on RNS test in proximal muscles.

Для цитирования: Liik Maarika, Punga Anna Rostedt. Repetitive nerve stimulation often fails to detect abnormal decrement in acute severe generalized Myasthenia Gravis.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2016. DOI: 10.1016/j.clinph.2016.09.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.