MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/wnp.0000000000000285

Медицинская библиотека · Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society · 2016

Diagnostic Accuracy of Single Fiber Electromyography for Myasthenia Gravis in Patients Followed Longitudinally.

Morren John A, Levin Kerry H, Shields Robert W

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The literature lacks data on accuracy of single fiber electromyography (SFEMG) for myasthenia gravis (MG) patients followed longitudinally.

METHODS

We included patients with a clinical suspicion of MG who received SFEMG and follow-up at our institution between 2003 and 2013. Data collected included demographics, symptom details, clinical deficits, other diagnostic testing results, MG medication regimen, duration on treatment, response to therapy, and ultimate diagnosis after follow-up. When available, information was also extracted from the MG-specific Activities of Daily Living, MG Quality of Life, and European Quality of Life assessments before and after SFEMG.

RESULTS

Three hundred forty eight SFEMG patients met inclusion criteria. Myasthenia gravis was ultimately diagnosed in 31% (19% ocular, 12% generalized). A sensitivity of 78% was seen for MG regardless of subtype, 73% for ocular MG, and 85% for generalized MG. A specificity of 91% was obtained for MG of either ocular or generalized subtype.

CONCLUSIONS

The diagnostic accuracy of SFEMG using this methodology minimizing incorporation bias is more reliable than that usually described in previous studies. There is utility in increasing diagnostic yield when SFEMG results are combined with clinical data and those from other diagnostic tests, particularly serology.

Для цитирования: Morren John A, Levin Kerry H, Shields Robert W. Diagnostic Accuracy of Single Fiber Electromyography for Myasthenia Gravis in Patients Followed Longitudinally.. Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society. 2016. DOI: 10.1097/wnp.0000000000000285.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.