MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.ju.0000158446.21396.c0

Медицинская библиотека · The Journal of urology · 2005

Clitoral anatomy in nulliparous, healthy, premenopausal volunteers using unenhanced magnetic resonance imaging.

O'Connell Helen E, DeLancey John O L

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We determined the magnetic resonance imaging (MRI) characteristics of normal clitoral anatomy.

MATERIALS AND

METHODS

A series of MRI studies of 10 healthy, nulliparous volunteers with no prior surgery and normal pelvic examination was studied and the key characteristics of clitoral anatomy were determined. A range of different magnetic resonance sequences was used without any contrast agent.

RESULTS

The axial plane best revealed the clitoral body and its proximal continuation as the paired crura. The glans was seen more caudal than the body of the clitoris. The bulbs of the clitoris had the same signal as the rest of the clitoris in the axial plane and they related consistently to the other erectile structures. The bulbs, body and crura formed an erectile tissue cluster, namely the clitoris. In turn, the clitoris partially surrounded the urethra and vagina, forming a consistently observed tissue complex. Midline sagittal section revealed the shape of the body, although in this plane the rest of the clitoris was poorly displayed. The coronal plane revealed the relationship between the clitoral body and labia. The axial section cephalad to the clitoral body best revealed the vascular component of the neurovascular bundle to the clitoris. The fat saturation sequence particularly highlighted clitoral anatomy in healthy, premenopausal, nulliparous women.

CONCLUSIONS

Normal clitoral anatomy has been clearly demonstrated using noncontrast pelvic MRI.

Для цитирования: O'Connell Helen E, DeLancey John O L. Clitoral anatomy in nulliparous, healthy, premenopausal volunteers using unenhanced magnetic resonance imaging.. The Journal of urology. 2005. DOI: 10.1097/01.ju.0000158446.21396.c0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.