DOI 10.1097/01.ju.0000140760.79893.f1
Evaluation of autonomic innervation of the clitoris and bulb.
Аннотация
PURPOSE: Female sexual dysfunction is a common disorder but there are few objective measures of female genital function. We present a novel technique to record electrical activity of the female genital erectile tissue.
MATERIALS AND METHOD: We placed concentric needle electrodes in the right clitoral crus and the bulb of 22 healthy women. Following spontaneous activity recording we stimulated the median nerve to activate the sympathetic nervous system. We simultaneously measured evoked activity in the clitoris and bulb, and hand sympathetic skin responses (SSRs).
RESULTS
Spontaneous electrical activity of the clitoris and bulb was present in 13 subjects. A total of 21 subjects had evoked activity in the bulb, while 18 had evoked activity in the clitoris. All subjects had hand SSRs. Evoked genital response latencies were similar to hand SSR latency (p > 0.05). Evoked electrical activity was recordable in the clitoris and bulb but it was more easily performed in the bulb.
CONCLUSIONS
Evoked electrical activity is more consistently obtained than spontaneous activity. These tests represent possible objective measures of female genital autonomic innervation, which may have relevance to female sexual function.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.