m+Medelevator.RU
← Поиск публикаций
Archives of cardiovascular diseases · 2017

Immediate and 1-year follow-up with the novel nanosurface modified COBRA PzF stent.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Maillard Luc, Tavildari Alain, Barra Nicolas, Billé Jacques, Joly Patrick, Peycher Patrick, Silvestri Marc, Vochelet François

Аннотация

BACKGROUND: The COBRA PzF coronary stent, which has a unique nano-coating of Polyzene-F, was developed to reduce the risk of stent thrombosis.

AIMS: To report procedural and 1-year clinical outcomes following COBRA PzF coronary stent implantation in a real-world percutaneous coronary intervention (PCI) registry.

METHODS: All patients assigned to treatment with the COBRA PzF in the GCS Axium Rambot Center, Aix-en-Provence, France between February 2013 to June 2014 were prospectively enrolled.

RESULTS: Among 100 patients (71% men, mean±standard error age 71.4±11.0 years), 38% had acute coronary syndromes. The population was consistent with real-world experience and included patients with multiple co-morbidities and 26% with diffuse multivessel disease. A total of 151 lesions were treated with 166 stents, including 26% of lesions with a type B2 or C classification. Pre- and post-procedural quantitative coronary angiography analyses showed a mean acute gain of 2.2±0.2mm. Angiographic success was achieved in all cases. One-year follow-up was available for all patients and the target vessel failure (composite of all-cause mortality, myocardial infarction or target vessel revascularization) rate was 12%, including 2% mortality (end-stage cardiomyopathy), 5% myocardial infarction (five periprocedural myocardial infarctions with isolated troponin elevation without chest pain or Q waves) and 5% target lesion revascularization. There were no cases of definite stent thrombosis.

CONCLUSION: The COBRA PzF stent was safe and effective in routine practice. One-year follow-up was associated with excellent clinical outcomes and compared favourably with current devices. These results are very promising in a real-world population of complex patients, and further study is warranted.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты