MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2017-311983

Медицинская библиотека · Heart (British Cardiac Society) · 2017

Assessment of the 2016 National Institute for Health and Care Excellence high-sensitivity troponin rule-out strategy.

Carlton Edward Watts, Pickering John William, Greenslade Jaimi, Cullen Louise, Than Martin, Kendall Jason, Body Richard, Parsonage William A, Khattab Ahmed, Greaves Kim

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

We aimed to evaluate the limit of detection of high-sensitivity troponin (hs-cTn) and Thrombolysis In Myocardial Infarction (TIMI) score combination rule-out strategy suggested within the 2016 National Institute for Health and Care Excellence (NICE) Chest Pain of Recent Onset guidelines and establish the optimal TIMI score threshold for clinical use.

METHODS

A pooled analysis of adult patients presenting to the emergency department with chest pain and a non-ischaemic ECG, recruited into six prospective studies, from Australia, New Zealand and the UK. We evaluated the sensitivity of TIMI score thresholds from 0 to 2 alongside hs-cTnT or hs-cTnI for the primary outcome of major adverse cardiac events within 30 days.

RESULTS

Data were available for 3159 patients for hs-cTnT and 4532 for hs-cTnI, of these 376 (11.9%) and 445 (9.8%) had major adverse cardiac events, respectively. Using a TIMI score of 0, the sensitivity for the primary outcome was 99.5% (95% CI 98.1% to 99.9%) alongside hs-cTnT and 98.9% (97.4% to 99.6%)%) alongside hs-cTnI, identifying 17.9% and 21.0% of patients as low risk, respectively. For a TIMI score ≤1 sensitivity was 98.9% (97.3% to 99.7%)%) alongside hs-cTnT and 98.4% (96.8% to 99.4%)%) alongside hs-cTnI, identifying 28.1% and 35.7% as low risk, respectively. For TIMI≤2, meta-sensitivity was <98% with either assay.

CONCLUSIONS

Our findings support the rule-out strategy suggested by NICE. The TIMI score threshold suggested for clinical use is 0. The proportion of patients identified as low risk (18%-21%) and suitable for early discharge using this threshold may be sufficient to encourage change of practice.

TRIAL REGISTRATION NUMBERS: ADAPT observational study/IMPACT intervention trial ACTRN12611001069943.ADAPT-ADP randomised controlled trial ACTRN12610000766011. EDACS-ADP randomised controlled trial ACTRN12613000745741. TRUST observational study ISRCTN no. 21109279.

Для цитирования: Carlton Edward Watts, Pickering John William, Greenslade Jaimi, Cullen Louise, Than Martin, Kendall Jason, Body Richard, Parsonage William A, Khattab Ahmed, Greaves Kim. Assessment of the 2016 National Institute for Health and Care Excellence high-sensitivity troponin rule-out strategy.. Heart (British Cardiac Society). 2017. DOI: 10.1136/heartjnl-2017-311983.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.