Hata Reo, Oka Naoki, Kubo Shunsuke, Kuwayama Akimune, Ohya Masanobu, Shimada Takenobu, Miura Katsuya, Amano Hidewo, Hyodo Yusuke, Otsuru Suguru, Habara Seiji, Tada Takeshi, Tanaka Hiroyuki, Fuku Yasushi, Goto Tsuyoshi, Kadota Kazushige
Аннотация
BACKGROUND: Little is known about the impact of stent type on the prognosis of vasospastic angina (VSA) in patients who undergo stent implantation.
METHODS AND RESULTS: We evaluated consecutive patients undergoing coronary angiography with positive (n=650; VSA) and negative (n=2,872; non-VSA) ergonovine testing. Among them, 304 patients undergoing stent implantation for organic stenosis were classified for comparison into 3 respective VSA and non-VSA groups based on stent type (68 and 78 with bare-metal stent [BMS]; 21 and 49 with sirolimus-eluting stent [SES]; 26 and 62 with newer generation drug-eluting stent [N-DES]). The primary outcome was defined as target lesion revascularization, target vessel revascularization, emergency coronary angiography, and cardiac death. The 2-year cumulative incidence of the primary outcome was significantly higher in the VSA group than non-VSA group after SES implantation (38.1% vs. 16.1%, P=0.03), whereas there were no differences between the 2 groups after both BMS implantation and N-DES implantation. The difference in the percent diameter stenosis from mid-term to late-term follow-up was significantly higher in the VSA group than non-VSA group (10.0% vs. 2.3%, P=0.045) after SES implantation, whereas there were no differences between the 2 groups after both BMS implantation and N-DES implantation.
CONCLUSIONS: The impact of VSA on clinical and angiographic outcomes was observed only in SES implantation, but not after N-DES or BMS implantation.
METHODS AND RESULTS: We evaluated consecutive patients undergoing coronary angiography with positive (n=650; VSA) and negative (n=2,872; non-VSA) ergonovine testing. Among them, 304 patients undergoing stent implantation for organic stenosis were classified for comparison into 3 respective VSA and non-VSA groups based on stent type (68 and 78 with bare-metal stent [BMS]; 21 and 49 with sirolimus-eluting stent [SES]; 26 and 62 with newer generation drug-eluting stent [N-DES]). The primary outcome was defined as target lesion revascularization, target vessel revascularization, emergency coronary angiography, and cardiac death. The 2-year cumulative incidence of the primary outcome was significantly higher in the VSA group than non-VSA group after SES implantation (38.1% vs. 16.1%, P=0.03), whereas there were no differences between the 2 groups after both BMS implantation and N-DES implantation. The difference in the percent diameter stenosis from mid-term to late-term follow-up was significantly higher in the VSA group than non-VSA group (10.0% vs. 2.3%, P=0.045) after SES implantation, whereas there were no differences between the 2 groups after both BMS implantation and N-DES implantation.
CONCLUSIONS: The impact of VSA on clinical and angiographic outcomes was observed only in SES implantation, but not after N-DES or BMS implantation.