m+Medelevator.RU
← Поиск публикаций
Journal of cardiothoracic surgery · 2023

Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch.

ОбзорСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Rasheed Nabeel F, Stonebraker Corinne, Li Zhaozhi, Siddiqi Umar, Lee Andy C H, Li Willa, Lupo Sydney, Cruz Jennifer, Cohen William G, Staub Cathy, Rodgers Daniel, Myren Mark, Combs Pamela, Jeevanandam Valluvan, Hibino Narutoshi

Аннотация

BACKGROUND: While the pledget suture technique has been the standard for surgical aortic. valve replacement (AVR), discussion continues regarding the possibility of the nonpledget suture technique to produce superior structural and hemodynamic parameters. This study aims to assess the effectiveness of the figure-of-eight suture technique in AVR, as determined by the incidence of prosthesis-patient mismatch (PPM).

METHODS: We reviewed records of patients (N = 629) who underwent a surgical AVR procedure between January 2011 and July 2018 at a single institution. Indexed effective orifice area values and PPM incidence were calculated from implanted valve size and patient body surface area. Incidence of none, moderate, and severe PPM was compared across AVR suture techniques.

RESULTS: A total of 570 pledget and 59 figure-of-eight patients were compared for incidence of PPM. Patients who received AVR with the pledget suture technique had significantly lower echocardiographic measurements of baseline ejection fraction than patients who had received AVR with the figure-of-eight suture technique (p = 0.003). Patients who received the figure-of eight suture had a 14% decrease in moderate PPM compared to patients who received the pledget suture (p = 0.022). Patients who received the figure-of-eight suture also had a significantly higher rate of no PPM (p = 0.044).

CONCLUSIONS: The use of the figure-of-eight suture technique in AVR can reduce the incidence of moderate PPM. While the pledget suture is the standard technique in AVR, the figure-of-eight suture technique may offer better structural and hemodynamic outcomes, especially for patients with a smaller aortic annulus.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты