Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2023

Outcomes with plug-based versus suture-based vascular closure device after transfemoral transcatheter aortic valve replacement: A systematic review and meta-analysis.

МетаанализСистематический обзорСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Sedhom Ramy, Dang Alexander T, Elwagdy Amr, Megaly Michael, Elgendy Islam Y, Zahr Firas, Gafoor Samir, Mamas Mamas, Elbadawi Ayman

Аннотация

BACKGROUND: Studies comparing plug-based (i.e., MANTA) with suture-based (i.e., ProStar XL and ProGlide) vascular closure devices (VCDs) for large-bore access closure after transcatheter aortic valve replacement (TAVR) have yielded mixed results.

AIMS: To examine the comparative safety and efficacy of both types of VCDs among TAVR recipients.

METHODS: An electronic database search was performed through March 2022 for studies comparing access-site related vascular complications with plug-based versus suture-based VCDs for large-bore access site closure after transfemoral (TF) TAVR.

RESULTS: Ten studies (2 randomized controlled trials [RCTs] and 8 observational studies) with 3113 patients (MANTA = 1358, ProGlide/ProStar XL = 1755) were included. There was no difference between plug-based and suture-based VCD in the incidence of access-site major vascular complications (3.1% vs. 3.3%, odds ratio [OR]: 0.89; 95% confidence interval [CI]: 0.52-1.53). The incidence of VCD failure was lower in plug-based VCD (5.2% vs. 7.1%, OR: 0.64; 95% CI: 0.44-0.91). There was a trend toward a higher incidence of unplanned vascular intervention in plug-based VCD (8.2% vs. 5.9%, OR: 1.35; 95% CI: 0.97-1.89). Length of stay was shorter with MANTA. Subgroup analyses suggested significant interaction based on study designs such that there was higher incidence of access-site vascular complications and bleeding events with plug-based versus suture-based VCD among RCTs.

CONCLUSION: In patients undergoing TF-TAVR, large-bore access site closure with plug-based VCD was associated with a similar safety profile as suture-based VCD. However, subgroup analysis showed that plug-based VCD was associated with higher incidence of vascular and bleeding complications in RCTs.