MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/icl.0000000000000410

Медицинская библиотека · Eye & contact lens · 2018

Efficacy of Amphotericin B Against Fusarium and Aspergillus in Corneal Storage Medium.

Duncan Katherine, Parker Jeff, Hoover Caroline, Lindquist Thomas D, Jeng Bennie H

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The incidence of postkeratoplasty fungal infection is increasing in the United States, and our most commonly used corneal storage medium, Optisol-GS, contains antibiotics but no antifungal agents. We previously demonstrated the efficacy of amphotericin B additives in eliminating Candida albicans contaminants in Optisol-GS. The purpose of this study was to determine whether amphotericin B would also be efficacious against Fusarium solani and Aspergillus fumigatus.

METHODS

Vials of Optisol-GS were supplemented with 0.255 μg/mL of amphotericin B. Half of the vials were inoculated with F. solani and half with A. fumigatus. Positive control vials were inoculated with the fungi but no amphotericin B. The vials were refrigerated, sampled, and plated at different time points. The plates were then incubated at 36°C for 48 hr after which fungal colony counts were performed.

RESULTS

There was an average reduction in the growth of F. solani in the amphotericin B-supplemented vials of 44% on day 2, 79% on day 7, and 80% on day 14 when compared with the positive control vials. There was an average reduction in the growth of A. fumigatus in the amphotericin B-supplemented vials of 40% on day 2 and 14% on day 7 when compared with the positive control vials. Both amphotericin B-supplemented and control vials grew less than 2 colonies of A. fumigatus on day 14.

CONCLUSIONS

This study suggests that amphotericin B additives in Optisol-GS reduce the growth of F. solani and A. fumigatus.

Для цитирования: Duncan Katherine, Parker Jeff, Hoover Caroline, Lindquist Thomas D, Jeng Bennie H. Efficacy of Amphotericin B Against Fusarium and Aspergillus in Corneal Storage Medium.. Eye & contact lens. 2018. DOI: 10.1097/icl.0000000000000410.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.