MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1537-2995.2008.01826.x

Медицинская библиотека · Transfusion · 2008

Cryoprecipitate use in 25 Canadian hospitals: commonly used outside of the published guidelines.

Alport Edward C, Callum Jeannie L, Nahirniak Susan, Eurich Bernie, Hume Heather A

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Canadian Blood Services' disposition reports suggested considerable variation in cryoprecipitate use and prompted this national audit.

STUDY DESIGN AND

METHODS

Thirty-one institutions were invited to participate in a 2-month audit. Patient information and relevant laboratory and transfusion data were collected. Cryoprecipitate transfusions were categorized as appropriate if a fibrinogen level (taken 6 hr before/after transfusion) was not more than 1.0 g per L and inappropriate if the pretransfusion fibrinogen level was more than 1.0 g per L and posttransfusion fibrinogen level was more than 1.0 g per L or not performed. Appropriateness was categorized as undetermined if the pretransfusion fibrinogen level was not performed and the posttransfusion fibrinogen level was more than 1.0 g per L or not performed.

RESULTS

Overall, 25 of 31 invited hospitals agreed to participate. A total of 4370 units of cryoprecipitate were transfused in 603 events to 453 patients representing 62 percent of cryoprecipitate issued to hospitals during the time period. Comparison of the number of units of cryoprecipitate per 100 units of red blood cells (RBCs) transfused by each institution showed significant variation in practice (mean, 9 per 100 RBCs; range, 2 to 27 units). The single most common indication for cryoprecipitate was cardiac surgery (45.4% of events). Overall, 24 percent of cryoprecipitate transfusions were considered to be appropriate (pretransfusion fibrinogen level <or=1 g/L in 19% and posttransfusion fibrinogen level <or=1.0 g/L in another 5%), 34 percent were inappropriate, and in 42 percent appropriateness could not be determined.

CONCLUSION

A 2-month audit of cryoprecipitate use in Canada revealed that the majority of cryoprecipitate use in Canada is not in accordance with published guidelines.

Для цитирования: Alport Edward C, Callum Jeannie L, Nahirniak Susan, Eurich Bernie, Hume Heather A. Cryoprecipitate use in 25 Canadian hospitals: commonly used outside of the published guidelines.. Transfusion. 2008. DOI: 10.1111/j.1537-2995.2008.01826.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.