m+Medelevator.RU
← Поиск публикаций
IEEE transactions on biomedical circuits and systems · 2024

Second-Order Level-Crossing Sampling Analog to Digital Converter for Electrocardiogram Delineation and Premature Ventricular Contraction Detection.

СтатьяПоддержка правительства СШАПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tang Xiaochen, Renteria-Pinon Mario, Tang Wei

Аннотация

This article presents an electrocardiogram (ECG) delineation and arrhythmia heartbeat detection system using a novel second-order level-crossing sampling analog to digital converter (ADC) for real-time data compression and feature extraction. The proposed system consists of the front-end integrated circuit of the data converter, the delineation algorithm, and the arrhythmia detection algorithm. Compared with conventional level-sampling ADCs, the proposed circuit updates tracking thresholds using linear extrapolation, which forms a second-order level-crossing sampling ADC that has sloped sampling levels. The computing is done digitally and is implemented by modifying the digital control logic of a conventional Successive-approximation-register (SAR) ADC. The system separates the sampling and quantization processes and only selects the turning points in the input waveform for quantization. The output of the proposed data converter consists of both the digital value of the selected sampling points and the timestamp between the selected sampling points. The main advantages are data savings for the data converter and the following digital signal processing or communication circuits, which are ideal for low-power sensors. The test chip was fabricated using a 180 nm CMOS process. When sensing sparse signals such as ECG signals the proposed ADC achieves a compression factor of 8.33. The delineation algorithm uses a triangle filter method to locate the fiducial points and measures the intervals, slopes, and morphology of the QRS complex and the P/T waves. Those extracted features are then used in the arrhythmia heartbeat detection algorithm to identify Premature Ventricular Contraction (PVC). The overall performance of the system is evaluated using the MIT-BIH database and the QT database, which is also compared with the recently reported systems. The accuracy, sensitivity, specificity, PPV, and F1 score are 97.3%, 89.6%, 97.8%, 73.3%, and 0.81 for detecting PVC.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты