m+Medelevator.RU
← Поиск публикаций
The Journal of invasive cardiology · 2019

Initial Experience With GlideAssist to Facilitate Advancement of Orbital Atherectomy Prior to Plaque Modification of Severely Calcified Coronary Artery Lesions.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Michael S, Shlofmitz Evan, Rha Seung-Woon, Shlofmitz Richard

Аннотация

OBJECTIVES: We report our initial experience with GlideAssist (Cardiovascular Systems, Inc) to facilitate advancement of the orbital atherectomy crown prior to plaque modification of severely calcified coronary artery lesions.

BACKGROUND: Severe coronary artery calcification increases the complexity of percutaneous coronary intervention (PCI) and is also associated with worse clinical outcomes compared with PCI of non-calcified vessels. Orbital atherectomy is an effective tool to modify calcified plaque prior to stenting. However, advancement of the orbital atherectomy crown may be technically challenging due to complex coronary anatomy.

METHODS: From February 2018 to February 2019, GlideAssist was used in 13 patients at the University of California, Los Angeles Medical Center. The primary endpoint was the 30-day rate of major adverse cardiac and cerebrovascular events, which was the composite of death, myocardial infarction (MI), target-vessel revascularization (TVR), and stroke.

RESULTS: Reasons for use of GlideAssist included severe angulation/tortuosity (76.9%), ostial lesion (15.4%), and presence of previously implanted stent proximal to the calcified target lesion (7.7%). All patients who required GlideAssist had successful delivery of the crown to the calcified lesion. One patient experienced a major adverse cardiac and cerebrovascular event, which was due to periprocedural MI that was due to coronary dissection. The same patient experienced subacute stent thrombosis 13 days after the index PCI requiring TVR. No patient died or had a stroke. No other angiographic complication occurred.

CONCLUSIONS: The GlideAssist function is a useful feature of the orbital atherectomy system to facilitate successful delivery of the crown in complex coronary anatomy.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты