International journal of cardiology · 2019
Peri-procedural thrombocytopenia after aortic bioprosthesis implant: A systematic review and meta-analysis comparison among conventional, stentless, rapid-deployment, and transcatheter valves.
Сравнительное исследованиеСтатьяМетаанализСистематический обзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Jiritano Federica, Santarpino Giuseppe, Serraino Giuseppe Filiberto, Ten Cate Hugo, Matteucci Matteo, Fina Dario, Mastroroberto Pasquale, Lorusso Roberto
Аннотация
BACKGROUND: Thrombocytopenia has been shown to occur soon after surgical biological aortic valve replacement (AVR), and recently reported also after transcatheter valve implantation (TAVI). The mechanism underlying this phenomenon is still unknown, and its clinical impact on the peri-operative outcome has been poorly investigated.
METHODS: A systematic review and a meta-analysis of all available studies reporting data about peri-procedural thrombocytopenia on isolated bio-AVR, comparing rapid-deployment (RDV), stentless (stentless-AVR), and TAVI vs. stented (stented-AVR) valves, have been performed.
RESULTS: Fifteen trials (2.163 patients) were included in the meta-analysis. Perioperative platelet reduction ranged from 35% to 55% in stented-AVR, from 60% to 77% in stentless-AVR, from 53% to 60% in RDV, and from to 21% to 72% in TAVI (apparently, balloon-expandable valves more frequently associated to thrombocytopenia). Stented-AVR required more red blood cells transfusion than stentless-AVR (P < 0.0001), whereas no difference has been found between RDV and stented-AVR. Platelet transfusion rate was very low in all surgical groups. No difference has been found in RDV and stentless-AVR vs. stented-AVR, in terms of reoperation for bleeding, and length-of-intensive care unit or hospital stay.
CONCLUSIONS: Thrombocytopenia-related major adverse events were mainly reported in TAVI patients, whereas clinically meaningless in surgical patients. Transient peri-procedural thrombocytopenia is common after bio-AVR, regardless of prosthesis's type or implant modality. It should receive appropriate monitoring and focused investigations.
METHODS: A systematic review and a meta-analysis of all available studies reporting data about peri-procedural thrombocytopenia on isolated bio-AVR, comparing rapid-deployment (RDV), stentless (stentless-AVR), and TAVI vs. stented (stented-AVR) valves, have been performed.
RESULTS: Fifteen trials (2.163 patients) were included in the meta-analysis. Perioperative platelet reduction ranged from 35% to 55% in stented-AVR, from 60% to 77% in stentless-AVR, from 53% to 60% in RDV, and from to 21% to 72% in TAVI (apparently, balloon-expandable valves more frequently associated to thrombocytopenia). Stented-AVR required more red blood cells transfusion than stentless-AVR (P < 0.0001), whereas no difference has been found between RDV and stented-AVR. Platelet transfusion rate was very low in all surgical groups. No difference has been found in RDV and stentless-AVR vs. stented-AVR, in terms of reoperation for bleeding, and length-of-intensive care unit or hospital stay.
CONCLUSIONS: Thrombocytopenia-related major adverse events were mainly reported in TAVI patients, whereas clinically meaningless in surgical patients. Transient peri-procedural thrombocytopenia is common after bio-AVR, regardless of prosthesis's type or implant modality. It should receive appropriate monitoring and focused investigations.