Vibration Sensitivity Is Associated With Functional Balance After Unilateral Transtibial Amputation.

Seth Mayank, Beisheim-Ryan Emma H, Pohlig Ryan T, Horne John Robert, Hicks Gregory E, Sions Jaclyn M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To evaluate differences in vibration perception thresholds between adults with transtibial amputation and age-matched adults without amputation and to examine associations between vibration perception thresholds and balance performance. We hypothesized that adults with transtibial amputation would demonstrate lower thresholds compared with adults without amputation and that lower thresholds would be associated with better functional balance.

DESIGN

Prospective cross-sectional study.

SETTING

National conference, clinical practice, and university laboratory.

PARTICIPANTS

Adults (N=34) with a nondysvascular, unilateral, transtibial amputation and 43 age-matched controls without amputation.

INTERVENTIONS: Participants' vibration perception thresholds were evaluated bilaterally by applying a vibration stimulus to the midpatella and recording their verbal response to conscious perception of stimulus. Functional balance was assessed with the Berg Balance Scale and the Four Square Step Test.

MAIN OUTCOME MEASURES: Residual and sound limb (right and left for controls) vibration perception thresholds, Berg Balance Scale, and Four Square Step Test.

RESULTS

For participants with transtibial amputation and controls, there were no significant between-group (P=.921) or interlimb (P=.540) differences in vibration perception thresholds. Overall, robust regression models explained 35.1% and 19.3% variance in Berg Balance Scale scores and Four Square Step Test times, respectively. Among adults with transtibial amputation, vibration perception thresholds were negatively associated with Berg Balance Scale scores (P=.009) and positively associated with Four Square Step Test times (P=.048). Among controls, average vibration perception thresholds were not significantly associated with functional balance (P>.050).

CONCLUSIONS

Adults with nondysvascular, transtibial-level amputation demonstrated similar vibration detection compared with adults with intact limbs, indicating that vibration detection is preserved in the amputated region postamputation. These findings suggest a unique relationship between vibration perception and functional balance post-transtibial amputation.

Для цитирования: Seth Mayank, Beisheim-Ryan Emma H, Pohlig Ryan T, Horne John Robert, Hicks Gregory E, Sions Jaclyn M. Vibration Sensitivity Is Associated With Functional Balance After Unilateral Transtibial Amputation.. Archives of rehabilitation research and clinical translation. 2021. DOI: 10.1016/j.arrct.2021.100161.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.