MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tbme.2021.3137756

Медицинская библиотека · IEEE transactions on bio-medical engineering · 2022

Wearables Detect Malaria Early in a Controlled Human-Infection Study.

Chaudhury Sidhartha, Yu Chenggang, Liu Ruifeng, Kumar Kamal, Hornby Samantha, Duplessis Christopher, Sklar Joel M, Epstein Judith E, Reifman Jaques

СтатьяПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Observational studies on the use of commercially available wearable devices for infection detection lack the rigor of controlled clinical studies, where time of exposure and onset of infection are exactly known. Towards that end, we carried out a feasibility study using a commercial smartwatch for monitoring heart rate, skin temperature, and body acceleration on subjects as they underwent a controlled human malaria infection (CHMI) challenge.

METHODS

Ten subjects underwent CHMI and were asked to wear the smartwatch for at least 12 hours/day from 2 weeks pre-challenge to 4 weeks post-challenge. Using these data, we developed 2B-Healthy, a Bayesian-based infection-prediction algorithm that estimates a probability of infection. We also collected data from eight control subjects for 4 weeks to assess the false-positive rate of 2B-Healthy.

RESULTS

Nine of 10 CHMI subjects developed parasitemia, with an average time to parasitemia of 12 days. 2B-Healthy detected infection in seven of nine subjects (78% sensitivity), where in six subjects it detected infection 6 days before parasitemia (on average). In the eight control subjects, we obtained a false-positive rate of 6%/week.

CONCLUSION

The 2B-Healthy algorithm was able to reliably detect infection prior to the onset of symptoms using data collected from a commercial smartwatch in a controlled human infection study.

SIGNIFICANCE: Our findings demonstrate the feasibility of wearables as a screening tool to provide early warning of infection and support further research on the use of the 2B-Healthy algorithm as the basis for a wearable infection-detection platform.

Для цитирования: Chaudhury Sidhartha, Yu Chenggang, Liu Ruifeng, Kumar Kamal, Hornby Samantha, Duplessis Christopher, Sklar Joel M, Epstein Judith E, Reifman Jaques. Wearables Detect Malaria Early in a Controlled Human-Infection Study.. IEEE transactions on bio-medical engineering. 2022. DOI: 10.1109/tbme.2021.3137756.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.