MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/eurheartj/ehag329

Медицинская библиотека · European heart journal · 2026

Tetralogy of Fallot: electrophysiology-guided surgical ablation during pulmonary valve replacement.

Dib Nabil, Poirier Nancy, Kamp Anna, Seslar Stephen P, Robinson Melissa R, Alonso Pablo Avila, Honfo Sewanou Hermann, Bessière Francis, Waldmann Victor, Dore Annie, Mongeon François-Pierre, Bouhout Ismail, Chaix Marie-A, Ibrahim Reda, Dyrda Katia, Raymond-Paquin Alexandre, Cadrin-Tourigny Julia, Petzl Adrian M, Tadros Rafik, Aguilar Martin, Guerra Peter G, Rivard Lena, Macle Laurent, Thibault Bernard, Roy Denis, Mondésert Blandine, Khairy Paul

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Adults with repaired tetralogy of Fallot (TOF) face long-term risks of ventricular tachycardia (VT) and sudden cardiac death (SCD). There is no consensus on arrhythmia management during surgical pulmonary valve replacement (PVR). This study assessed whether pre-operative electrophysiological (EP) testing with targeted intraoperative cryoablation of identified anatomical isthmuses during PVR is associated with a reduction in post-operative VT inducibility and long-term risk of clinical VT/SCD.

METHODS

In this prospective multicentre cohort study, consecutive adults with TOF undergoing surgical PVR (2005-22) underwent standardized pre-operative EP studies. Surgical ablation strategy (EP-guided vs empiric) was at the discretion of the treating team. Post-operative EP studies assessed residual inducibility; clinical VT/SCD were evaluated during follow-up.

RESULTS

Among 204 patients (age 35.5 ± 13.1 years, 43.1% female), 91 (45.1%) had inducible VT. Among those undergoing surgical ablation, post-operative VT was non-inducible in 74.1% with EP-guided vs 15.0% with empiric ablation [adjusted odds ratio 20.4, 95% confidence interval (CI) 4.5-91.8, P < .0001]. Persistent post-operative inducibility was associated with increased hazard of VT/SCD compared to patients without inducible VT pre-operatively [adjusted hazard ratio (HR) 5.3, 95% CI 1.8-16.0, P = .003], over a median 10.2-year follow-up. Compared to patients without inducible VT pre-operatively, empiric ablation was associated with a significantly higher hazard of VT/SCD (HR 5.2, 95% CI 1.6-16.5, P = .005), whereas EP-guided ablation was not (HR 2.8, 95% CI 0.8-10.3, P = .228).

CONCLUSIONS

In adults with repaired TOF undergoing PVR, inducible VT is common. An EP-guided surgical strategy is associated with greater post-operative non-inducibility and improved long-term arrhythmic outcomes compared with empiric ablation.

Для цитирования: Dib Nabil, Poirier Nancy, Kamp Anna, Seslar Stephen P, Robinson Melissa R, Alonso Pablo Avila, Honfo Sewanou Hermann, Bessière Francis, Waldmann Victor, Dore Annie, Mongeon François-Pierre, Bouhout Ismail, Chaix Marie-A, Ibrahim Reda, Dyrda Katia, Raymond-Paquin Alexandre, Cadrin-Tourigny Julia, Petzl Adrian M, Tadros Rafik, Aguilar Martin, Guerra Peter G, Rivard Lena, Macle Laurent, Thibault Bernard, Roy Denis, Mondésert Blandine, Khairy Paul. Tetralogy of Fallot: electrophysiology-guided surgical ablation during pulmonary valve replacement.. European heart journal. 2026. DOI: 10.1093/eurheartj/ehag329.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.