MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcin.2012.04.011

Медицинская библиотека · JACC. Cardiovascular interventions · 2012

Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation.

Vasa-Nicotera Mariuca, Sinning Jan-Malte, Chin Derek, Lim Tiong Keng, Spyt Tomasz, Jilaihawi Hasan, Grube Eberhard, Werner Nikos, Nickenig Georg, Kovac Jan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

The aim of this study was to evaluate the performance of the aortic regurgitation (AR) index as a new hemodynamic parameter in an independent transcatheter aortic valve implantation (TAVI) cohort and validate its application.

BACKGROUND

Increasing evidence associates more-than-mild periprosthetic aortic regurgitation (periAR) with increased mortality and morbidity; therefore precise evaluation of periAR after TAVI is essential. The AR index has been proposed recently as a simple and reproducible indicator for the severity of periAR and predictor of associated mortality.

METHODS

The severity of periAR was evaluated by echocardiography, angiography, and periprocedural measurement of the dimensionless AR index = ([diastolic blood pressure - left ventricular end-diastolic pressure]/systolic blood pressure) × 100. A cutoff value of 25 was used to identify patients at risk.

RESULTS

One hundred twenty-two patients underwent TAVI by use of either the Medtronic CoreValve (Medtronic, Minneapolis, Minnesota) (79.5%) or the Edwards-SAPIEN bioprosthesis (Edwards Lifesciences, Irvine, California) (20.5%). The AR index decreased stepwise from 29.4 ± 6.3 in patients without periAR (n = 26) to 28.0 ± 8.5 with mild periAR (n = 76), 19.6 ± 7.6 with moderate periAR (n = 18), and 7.6 ± 2.6 with severe periAR (n = 2) (p < 0.001). Patients with AR index <25 had a significantly increased 1-year mortality rate compared with patients with AR index ≥ 25 (42.3% vs. 14.3%; p < 0.001). Even in patients with none/mild periAR, the 1-year mortality risk could be further stratified by an AR index <25 (31.3% vs. 14.3%; p = 0.04).

CONCLUSIONS

The validity of the AR index could be confirmed in this independent TAVI cohort and provided prognostic information that was complementary to the severity of AR.

Для цитирования: Vasa-Nicotera Mariuca, Sinning Jan-Malte, Chin Derek, Lim Tiong Keng, Spyt Tomasz, Jilaihawi Hasan, Grube Eberhard, Werner Nikos, Nickenig Georg, Kovac Jan. Impact of paravalvular leakage on outcome in patients after transcatheter aortic valve implantation.. JACC. Cardiovascular interventions. 2012. DOI: 10.1016/j.jcin.2012.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.