MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacc.2011.12.015

Медицинская библиотека · Journal of the American College of Cardiology · 2012

3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.

Willson Alexander B, Webb John G, Labounty Troy M, Achenbach Stephan, Moss Robert, Wheeler Miriam, Thompson Christopher, Min James K, Gurvitch Ronen, Norgaard Bjarne L, Hague Cameron J, Toggweiler Stefan, Binder Ronald, Freeman Melanie, Poulter Rohan, Poulsen Steen, Wood David A, Leipsic Jonathon

Сравнительное исследованиеСтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study sought to analyze multidetector computed tomography (MDCT) 3-dimensional aortic annular dimensions for the prediction of paravalvular aortic regurgitation (PAR) following transcatheter aortic valve replacement (TAVR).

BACKGROUND

Moderate or severe PAR after TAVR is associated with increased morbidity and mortality.

METHODS

A total of 109 consecutive patients underwent MDCT pre-TAVR with a balloon expandable aortic valve. Differences between transcatheter heart valve (THV) size and MDCT measures of annular size (mean diameter, area, and circumference) were analyzed concerning prediction of PAR. Patients with THV malposition (n = 7) were excluded. In 50 patients, MDCT was repeated after TAVR to assess THV eccentricity (1 - short diameter/long diameter) and expansion (MDCT measured THV area/nominal THV area).

RESULTS

Moderate or severe PAR (13 of 102) was associated with THV undersizing (THV diameter - mean diameter = -0.7 ± 1.4 mm vs. 0.9 ± 1.8 mm for trivial to mild PAR, p < 0.01). The difference between THV size and MDCT annular size was predictive of PAR (mean diameter: area under the curve [AUC]: 0.81, 95% confidence interval [CI]: 0.68 to 0.88; area: AUC: 0.80, 95% CI: 0.65 to 0.90; circumference: AUC: 0.76, 95% CI: 0.59 to 0.91). Annular eccentricity was not associated with PAR (AUC: 0.58, 95% CI: 0.46 to 0.75). We found that 35.3% (36 of 102) and 45.1% (46 of 102) of THVs were undersized relative to the MDCT mean diameter and area, respectively. THV oversizing relative to the annular area was not associated with THV eccentricity or underexpansion (oversized vs. undersized THVs; expansion: 102.7 ± 5.3% vs. 106.1 ± 5.6%, p = 0.03; eccentricity: median: 1.7% [interquartile range: 1.4% to 3.0%] vs. 1.7% [interquartile range: 1.1% to 2.7%], p = 0.28).

CONCLUSIONS

MDCT-derived 3-dimensional aortic annular measurements are predictive of moderate or severe PAR following TAVR. Oversizing of THVs may reduce the risk of moderate or severe PAR.

Для цитирования: Willson Alexander B, Webb John G, Labounty Troy M, Achenbach Stephan, Moss Robert, Wheeler Miriam, Thompson Christopher, Min James K, Gurvitch Ronen, Norgaard Bjarne L, Hague Cameron J, Toggweiler Stefan, Binder Ronald, Freeman Melanie, Poulter Rohan, Poulsen Steen, Wood David A, Leipsic Jonathon. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis.. Journal of the American College of Cardiology. 2012. DOI: 10.1016/j.jacc.2011.12.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.