Integrated morphologic and functional assessment of the aortic root after different tissue valve root replacement procedures.

Torii Ryo, El-Hamamsy Ismail, Donya Mohamed, Babu-Narayan Sonya V, Ibrahim Michael, Kilner Philip J, Mohiaddin Raad H, Xu Xiao Yun, Yacoub Magdi H

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVES

This study was undertaken to explore aspects of the hemodynamic function of different biologic tissue aortic valve root replacements. We set out to image and display the spatiotemporal distributions of axially directed blood velocity through the aortic root.

METHODS

The flow velocities through a plane transecting the aortic root were measured by 2-dimensional cine phase-contrast magnetic resonance velocity mapping in 44 subjects: 29 patients who had undergone aortic root replacement approximately 10 years previously (13 autografts, 10 stentless xenografts, and 6 homografts) and 15 healthy control subjects. With cine as well as velocity images, aortic sinus dimensions, effective orifice area, and several velocity parameters were measured. Color-coded plots of velocity relative to the sinus cross sections and velocity-time plots were used to compare spatiotemporal distributions of velocity.

RESULTS

Peak flow velocity was similar between the autografts (102 ± 28.0 cm/s) and control valves (119 ± 20.0 cm/s) but was higher in xenografts (167 ± 36.0 cm/s) and homografts (206 ± 91.0 cm/s). These measurements showed an inverse relationship with the effective orifice area (7.27 ± 0.20, 4.24 ± 0.81, 3.37 ± 0.32, and 3.28 ± 0.87 cm(2), respectively). Autograft peak flow velocity showed no significant difference from control valve peak flow velocity, despite larger root dimensions (P < .001). The graphic displays provided further spatiotemporal information.

CONCLUSIONS

Peak velocities and spatiotemporal flow patterns depend on the type of valve substitute. In the parameters measured, autograft replacements differed least from normal aortic valves.

Для цитирования: Torii Ryo, El-Hamamsy Ismail, Donya Mohamed, Babu-Narayan Sonya V, Ibrahim Michael, Kilner Philip J, Mohiaddin Raad H, Xu Xiao Yun, Yacoub Magdi H. Integrated morphologic and functional assessment of the aortic root after different tissue valve root replacement procedures.. The Journal of thoracic and cardiovascular surgery. 2012. DOI: 10.1016/j.jtcvs.2011.12.034.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.