MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euac104

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023

An evaluation of 24 h Holter monitoring in patients with myotonic dystrophy type 1.

Joosten Isis B T, Janssen Cheyenne E W, Horlings Corinne G C, den Uijl Dennis, Evertz Reinder, van Engelen Baziel G M, Faber Catharina G, Vernooy Kevin

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: To evaluate the clinical effectiveness of routine 24 h Holter monitoring to screen for conduction disturbances and arrhythmias in patients with myotonic dystrophy type 1 (DM1).

METHODS AND

RESULTS

A retrospective two-centre study was conducted including DM1-affected individuals undergoing routine cardiac screening with at least one 24 h Holter monitoring between January 2010 and December 2020. For each individual, the following data were collected: Holter results, results of electrocardiograms (ECGs) performed at the same year as Holter monitoring, presence of cardiac complaints, and neuromuscular status. Holter findings were compared with the results of cardiac screening (ECG + history taking) performed at the same year. Cardiac conduction abnormalities and/or arrhythmias that would have remained undiagnosed based on history taking and ECG alone were considered de novo findings. A total 235 genetically confirmed DM1 patients were included. Abnormal Holter results were discovered in 126 (54%) patients after a mean follow-up of 64 ± 28 months in which an average of 3 ± 1 Holter recordings per patient was performed. Abnormalities upon Holter mainly consisted of conduction disorders (70%) such as atrioventricular (AV) block. Out of 126 patients with abnormal Holter findings, 74 (59%) patients had de novo Holter findings including second-degree AV block, atrial fibrillation/flutter and non-sustained ventricular tachycardia. Patient characteristics were unable to predict the occurrence of de novo Holter findings. In 39 out of 133 (29%) patients with normal ECGs upon yearly cardiac screening, abnormalities were found on Holter monitoring during follow-up.

CONCLUSION

Twenty-four hour Holter monitoring is of added value to routine cardiac screening for all DM1 patients.

Для цитирования: Joosten Isis B T, Janssen Cheyenne E W, Horlings Corinne G C, den Uijl Dennis, Evertz Reinder, van Engelen Baziel G M, Faber Catharina G, Vernooy Kevin. An evaluation of 24 h Holter monitoring in patients with myotonic dystrophy type 1.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2023. DOI: 10.1093/europace/euac104.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.