m+Medelevator.RU
← Поиск публикаций
Neurology · 2021

Accuracy of Cardiac Innervation Scintigraphy for Mild Cognitive Impairment With Lewy Bodies.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Roberts Gemma, Durcan Rory, Donaghy Paul C, Lawley Sarah, Ciafone Joanna, Hamilton Calum A, Colloby Sean J, Firbank Michael J, Allan Louise, Barnett Nicola, Barker Sally, Howe Kim, Ali Tamir, Petrides George S, Lloyd Jim, Taylor John-Paul, O'Brien John, Thomas Alan J

Аннотация

OBJECTIVE: To provide evidence that cardiac I-123-metaiodobenzylguanidine sympathetic innervation imaging (MIBG) scintigraphy differentiates probable mild cognitive impairment with Lewy bodies (MCI-LB) from mild cognitive impairment due to Alzheimer disease (MCI-AD), we scanned patients with MCI and obtained consensus clinical diagnoses of their MCI subtype. We also performed baseline FP-CIT scans to compare the accuracy of MIBG and FP-CIT.

METHODS: We conducted a prospective cohort study into the accuracy of cardiac MIBG scintigraphy in the diagnosis of MCI-LB. Follow-up clinical assessment was used to diagnose MCI-AD (no core features of MCI-LB and normal FP-CIT), probable MCI-LB (2 or more core features, or 1 core feature with abnormal FP-CIT), or possible MCI-LB (1 core feature or abnormal FP-CIT). For the comparison between MIBG and FP-CIT, only core clinical features were used for diagnosis.

RESULTS: We recruited 95 people with mild cognitive impairment. Cardiac MIBG was abnormal in 22/37 probable and 2/15 possible MCI-LB cases and normal in 38/43 MCI-AD cases. The sensitivity in probable MCI-LB was 59% (95% confidence interval [CI], 42%-75%), specificity 88% (75%-96%), and accuracy 75% (64%-84%). The positive likelihood ratio was 5.1 and negative likelihood ratio 0.46. With symptom-only diagnoses, the accuracies were 79% for MIBG (95% CI, 68%-87%) and 76% for FP-CIT (95% CI, 65%-85%).

CONCLUSIONS: Cardiac MIBG appears useful in early disease, with an abnormal scan highly suggestive of MCI-LB. Validation in a multicenter setting is justified.

CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that cardiac MIBG distinguishes MCI-LB from MCI-AD.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты