Role of diffusion weighted magnetic resonance imaging in a rat model of testicular torsion.

Ufuk Furkan, Herek Duygu, Herek Özkan, Akbulut Metin

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The purpose of this study was to investigate the usefulness of diffusion-weighted imaging (DWI) in the detection of different degrees of testicular torsion (TT) at the 8th hour and testicular salvageability at the 24th hour of torsion.

METHODS

31 rats were randomly classified into 4 groups. In Group 1 (sham-control group), the left testicle was kept outside and replaced. Left testicles were kept outside and twisted 360° in Group 2, 720° in Group 3 and 1080° in Group 4. Later, DWI was performed at 8th and 24th hours. After DWI, bilateral radical orchiectomy and histopathological examination were performed. Apparent diffusion coefficient (ADC) maps were obtained with b-factors of 0 and 800 s mm-2. Comparisons of ADC values and damage in testicles were performed with Kruskal-Wallis test.

RESULTS

Sensitivity of DWI in the diagnosis of TT was 12.5% for 360° torsion, 100% for 720° torsion and 1080° torsion at the 8th hour of torsion. Mean ADC values of the left testicles increased significantly at the 24th hour of torsion in Groups 3 and 4. All testicles in Groups 3 and 4 were observed to be irrecoverable on histopathological examination.

CONCLUSION

Increased ADC values in the affected testicle may represent irreversible tissue damage. So, immediate surgery is not required at this stage, which may reduce morbidity and mortality caused by immediate surgery and anaesthesia. Advances in knowledge: TT can be diagnosed easily by DWI without administrating any contrast material. DWI findings in the affected testicle may represent testicular salvageability.

Для цитирования: Ufuk Furkan, Herek Duygu, Herek Özkan, Akbulut Metin. Role of diffusion weighted magnetic resonance imaging in a rat model of testicular torsion.. The British journal of radiology. 2016. DOI: 10.1259/bjr.20160585.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.